S WA R F E N G I N E E R I N G VA C U U M SSIVD 1800 DH SSIVD 1800 PH SSIVD 1800 AP Owner Instructions Warning! Read instructions before using the machine www.numatic.co.uk...
Thank you for purchasing the Numatic Specialised Engineering Separator Swarf Vacuum, the product has been designed specifically to cater for the removal of swarf particlulates and coolant combined. The swarf / coolant is drawn into the machine via the cyclonic entrance and once inside falls into a collection basket where the coolant will drain through into the bottom drum assembly.
Assembling the vacuum Assemble the wand, floor tool and hose. Fit the reducer / adaptor to the cyclonic inlet and connect the suction hose. Drainage hose 10 metre hose. Open. Closed. Storage of DH / PH hose. DH / PH hose closure. Connection of AP hose.
PH / AP machine - Connect powered pump Located on the rear is the power lead from the pump, connect the lead into socket on the top of the machine. Operating the vacuum DH version (Dump Hose). Once plugged in to the power supply proceed to turn on the blue switch fitted to the handle of the head assembly (this activates the vac motor).
Page 5
AP version (Auto Pump). Secure the end of the 10 metre dump hose into a waste, disposal system, or return to the cutting machine. Once plugged into the power supply, proceed to turn on the blue switch fitted to the handle of the head assembly (this activates the vac motor).
Page 6
No 207124 Under the cartridge filter is the float cage assembly, check the metal mesh for damage and replace if required. Use genuine Numatic replacment float cage part No 502047 Clean the metal cage before reassembling the machine. part No 502047...
Page 7
Remove the three toggles that hold the plastic adaptor in place and remove. part No 0000-19 Lift out the swarf catchment basket using the bucket handle fitted to the top rim and empty. Please take care when lifting the basket as it may be heavy.
NOTE: A risk assessment should be conducted to determine which PPE should be worn. Safety Critical Component: In the event of a breakdown contact your Numatic dealer or the DH - Mains Lead: H05VV-F 10m x 1.5 mm x 2 Core PH / AP - Mains Lead: H05VV-F 10m x 1.5 mm...
Page 9
• Replace any worn or damaged parts immediately. • Regularly examine the power cord, if damage is found, power cord must be replaced by a qualified person using the correct Numatic original part. • Empty dust container frequently. • Keep diffuser filter (where fitted) clean.
After use always inspect the machine for damage. In the event of a breakdown contact your Numatic dealer or the Numatic Specialised help line +44 (0)1460 269401 Part No...
Need help?
Do you have a question about the SSIVD 1800 DH and is the answer not in the manual?