Connect the Gun Flush Box

NOTE: Use 5/32 in. (4 mm) OD tubing to connect the
gun flush box air ports to the interface module air ports,
as follows. See F
. 12.
IG
1. From the P port to the air supply.
2. From the A port to the pressure switch air input.
3. From the C port to the gun flush box solenoid out-
put.
4. From the S port to the atomizing air safety shutoff
valve pilot port. See the gun flush box manual for
details on the safety shutoff valve.
5. From the AFS to the atomizing air safety shutoff
valve IN port. See the gun flush box manual for
details on the safety shutoff valve.

Connect Air Supply to Module

Connect a 1/4 in. (6 mm) OD tube between a clean, dry
air supply (filtered to 10 microns) and the module air
inlet fitting (13). See Parts on page 11.
GUN FLUSH BOX
F
. 12: Gun Flush Box to Interface Module Air Connections
IG
313212B
P
A
P
A
C
S
C
S
AIR SAFETY
SHUTOFF VALVE

Replace the Cover

Reinstall the cover on the enclosure and secure with the
four captive screws.

Ground the Enclosure

Connect a ground wire (Y) from the enclosure's ground
screw (6) to a true earth ground. See F
Y
6
F
. 11. Ground the Enclosure
IG
INTERFACE MODULE
C
IN
TI13110b
Installation
. 11.
IG
TI14277a
AFS