NOTICES BEFORE REPAIRING

To make the best use of this equipment, make sure to
obey the following items when repairing (or mending).
1. Do not damage or melt the tunicate of the leading
wire on the AC1 side, including the power supply
cord.
2. Do not soil or stain the letters on the spec.
inscription plates, notice labels, fuse labels, etc.
3. When repairing the part extracted from the
conducted side of the board pattern, fix it firmly
with applying bond to the pattern and the part.
4. Restore the following items after repairing.
1) Conditions of soldering of the wires (especially,
the distance on the AC1 side).
2) Conditions of wiring, bundling of wires, etc.
3) Types of the wries.
4) Attachment conditions of all types of the insulation.
5. After repairing, always measure the insulation
resistance and perform the voltage-withstand test
(See Fig-1).
1) The insulation resistance must be 7.0 to 9.5 M
500V
when applying
per second.
2) In the voltage withstand test, apply 3.0 KV for 1
minute and check that the GO lamp lights.
*
Breaking current set to 10 mA.
*
Connect the safety checker as shown in Fig-1,
then measure the resistance and perform the test.
*
Do not touch the equipment during testing.
*
For details of the safety checker, refer to the supplied
Operation manual.
When servicing and checking on the TV, note the followings.
1. Keep the notices
As for the places which need special attentions, they
are indicated with the labels or seals on the cabinet,
chassis and parts. Make sure to keep the indications
and notices in the operation manual.
2. Avoid an electric shock.
There is a high voltage part inside. Avoid an electric
shock while the electric current is flowing.
3. Use the designated parts.
The parts in this equipment have the specific
characters of incombustibility and withstand voltage
for safety.
Therefore, the part which is replaced should be used
the part which has the same character. Especially as
to the important parts for safety which is indicated in
the circuit diagram or the table of parts as a
the designated parts must be used.
4. Put parts and wires in the original position after
assembling or wiring.
There are parts which use the insulation material
such as a tube or tape for safety, or which are
assembled so that these parts do not contact with
the printed board. The inside wiring is designed not
All manuals and user guides at all-guides.com
Safety checker (Model 7110, etc.)
5. Take care of the cathode-ray tube.
6. Avoid an X-ray.
mark,
!
7. Perform a safety check after servicing.
2
Insulation resistance: 7.0 to 9.5 M (500 V/s)
Voltage-withstand: 3.0 KV for 1 minute
Earth cable
AC cable
Fig-1
to get closer to the pyrogenic parts and high voltage
parts. Therefore, put these parts in the original
positions.
By setting an explosion-proof cathode-ray tube is set
in this equipment, safety is secured against
implosion.
However, when removing it or serving from
backward, it is dangerous to give a shock. Take
enough care to deal with it.
Safety is secured against an X-ray by considering
about the cathode-ray tube and the high voltage
peripheral circuit, etc. Therefore, when repairing the
high voltage peripheral circuit, use the designated
parts and do not change the circuit. Repairing
except indicates causes rising of high voltage, and
the cathode-ray tube emits an X-ray.
Confirm that the screws, parts and wiring which were
removed in order to service are put in the original
positions, or whether there are the portions which are
deteriorated around the places serviced.
Connect the earth cable
to the outside metal part
terminal.

Advertisement