Operating Manual
Soil Sample Minimizer
Version: 13/11/18
Umwelt-Geräte-Technik GmbH
Eberswalder Str. 58 | D-15374 Müncheberg
phone: +49 (0) 33 43 2 - 89 575 | fax: +49 (0) 33 43 2 - 89 573
e-Mail: info@ugt-online.de | www.ugt-online.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Soil Sample Minimizer and is the answer not in the manual?

Questions and answers

Summary of Contents for UGT Soil Sample Minimizer

  • Page 1 Operating Manual Soil Sample Minimizer Version: 13/11/18 Umwelt-Geräte-Technik GmbH Eberswalder Str. 58 | D-15374 Müncheberg phone: +49 (0) 33 43 2 - 89 575 | fax: +49 (0) 33 43 2 - 89 573 e-Mail: info@ugt-online.de | www.ugt-online.de...
  • Page 2: Table Of Contents

    2.1. Structure ........................... 6 2.2. Technical data ..........................6 3. Operating instructions ........................7 4. Maintenance ........................... 10 Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 2 of 10...
  • Page 3: Introduction

    • undisturbed soil structure is retained • Examinations in the µm range possible An additional service to this manual is our tutorial on the use of the soil sample minimizer which can be found at the following link: https://www.ugt-online.de/en/products/soil-science/soil-sampling/taking-undisturbed-samples-from- sample-ring-samples/ There are several ways to contact UGT if you ever need assistance with your product, have any questions, or feedback.
  • Page 4: Scope Of Supply

    The size and design of the lancet device for the subsample collection can vary according to the customer's requirements. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 4 of 10...
  • Page 5: General Information

    Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 5 of 10...
  • Page 6: Structure

    30 x 30 x 60 cm Weight of overall assembly 12 kg Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 6 of 10...
  • Page 7: Operating Instructions

    3. Operating instructions To gain subsamples from your soil sample by using the Soil Sample Minimizer attach the sample chamber to the mounting fixture for the soil sample chamber An Allen wrench of size 5 is needed for mounting. Make sure to only hand tighten the screw.
  • Page 8 Afterwards, put the locking lever back into the lock position (4). Insert the original soil sample into the sample holding chamber. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 8 of 10...
  • Page 9 Remove the soil sampling ring from the sampling ring adapter or from the mounting plate. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de Page 9 of 10...
  • Page 10: Maintenance

    4. Maintenance The Soil Sample Minimizer is maintenance-free. However, we recommend cleaning the device carefully after use to protect the mechanics from damage. Umwelt-Geräte-Technik GmbH | Eberswalder Str. 58 | D-15374 Müncheberg | phone: +49 (0) 33 43 2 - 89 575 | www.ugt-online.de...