Most common function blocks
The most common function blocks are listed below, see the full list from the operators manual.
Available function blocks varies depending on the selected IED and standard configuration.
Function
Three-phase non-directional overcurrent protection, low stage
Three-phase non-directional overcurrent protection, high stage
Three-phase non-directional overcurrent protection, instantaneous stage
Non-directional earth-fault protection, low stage
Non-directional earth-fault protection, high stage
Non-directional earth-fault protection, instantaneous stage
Directional earth-fault protection, low stage
Directional earth-fault protection, high stage
Transient / intermittent earth-fault protection
Negative-sequence overcurrent protection
Phase discontinuity protection
Residual overvoltage protection
Three-phase thermal protection for feeders
Loss of load supervision
Motor load jam protection
Motor start-up supervision
Phase reversal protection
Thermal overload protection for motors
Circuit breaker failure protection
Three-phase inrush detector
High-impedance differential protection
Phase segregated CT supervision function
Circuit-breaker control
Emergergency startup
Trip circuit supervision
Runtime counter for machines and devices
Disturbance recorder
Optional
Auto-reclosing
Complete customer documentation is available in the product pages that
can be accessed through abb.com/relion.
For more information, please contact
ABB Distribution Solutions
P.O. Box 699
FI-65101 Vaasa, Finland
Phone: + 358 10 22 11
abb.com/substationautomation
We reserve the right to make technical changes or modify the contents
of this document without prior notice. With regard to purchase orders,
the agreed particulars shall prevail. ABB does not accept any responsibility
whatsoever for potential errors or possible lack of information in this
document.
IEC 61850
PHLPTOC
PHHPTOC
PHIPTOC
EFLPTOC
EFHPTOC
EFIPTOC
DEFLPDEF
DEFHPDEF
INTRPTEF
NSPTOC
PDNSPTOC
ROVPTOV
T1PTTR
LOFLPTUC
JAMPTOC
STTPMSU
PREVPTOC
MPTTR
CCBRBRF
INRPHAR
HIPDIF
HZCCRDIF
CBXCBR
ESMGAPC
TCSSCBR
MDSOPT
RDRE
DARREC
We reserve all rights in this document and in the subject matter and
illustrations contained therein. Any reproduction, disclosure to third
parties or utilization of its contents – in whole or in parts – is forbidden
without prior written consent of ABB.
Copyright© 2019 ABB. All rights reserved.
IEC 60617
3I>
3I>>
3I>>>
Io>
Io>>
Io>>>
Io> →
Io>> →
Io> → IEF
I2>
I2/I1>
Uo>
3Ith>F
3I<
Ist>
Is2t n<
I2>>
3Ith>M
3I>/Io>BF
3I2f>
dHi>
MCS 1I
I ↔ O CB
ESTART
TCS
OPTS
DR
O → I