Sony EX480CP Technical Manual page 43

Color camera module
Table of Contents

Advertisement

VISCA Command/ACK Protocol
Command
Command Message
General Command
81 01 04 38 02 FF
(Example)
81 01 04 38 FF
(Example)
81 01 04 38 02 FF
(Example)
81 01 04 08 02 FF
(Example)
Inquiry Command
81 09 04 38 FF
(Example)
81 09 05 38 FF
(Example)
Address Set
88 30 01 FF
IF_Clear (Broadcast)
88 01 00 01 FF
IF_Clear (For x)
8x 01 00 01 FF
Command Cancel
8x 2y FF
Reply Message
Comments
90 41 FF (ACK)+90 51 FF
Returns ACK when a command has been accepted, and
(Completion)
Completion when a command has been executed.
90 42 FF
90 52 FF
90 60 02 FF (Syntax Error)
Accepted a command which is not supported or a command
lacking parameters.
90 60 03 FF
There are two commands currently being executed, and the
(Command Buffer Full)
command could not be accepted.
90 61 41 FF
Could not execute the command in the current mode.
(Command Not Executable)
90 62 41FF
90 50 02 FF (Completion)
ACK is not returned for the inquiry command.
90 60 02 FF (Syntax Error)
Accepted an incompatible command.
88 30 02 FF
Returned the device address to +1.
88 01 00 01 FF
Returned the same command.
z0 50 FF (Completion)
ACK is not returned for this command.
z0 6y 04 FF
Returned when the command of the socket specified is canceled.
(Command Canceled)
Completion for the command canceled is not returned.
z0 6y 05 FF (No Socket)
Returned when the command of the specified socket has already
been completed or when the socket number specified is wrong.
Command List