Sony EX480CP Technical Manual page 42

Color camera module
Table of Contents

Advertisement

VISCA Device Setting
Command
Before starting control of the FCB camera, be sure to
send the Address command and the IF_Clear
command using the broadcast function.
For VISCA Network Administration
● Address
Sets an address of a peripheral device. Use when
initializing the network and when receiving the
network change message indicated below.
● Network Change
Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.
Packet
Address
88 30 01 FF
Network Change
X0 38 FF
X = 9 to F: FCB camera address + 8
VISCA Interface Command
● IF_Clear
Clears the command buffers in the FCB camera and
cancels the command currently being executed.
Command Packet Reply Packet Note
IF_Clear
8X 01 00 01FF
IF_Clear (broadcast)
88 01 00 01 FF
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)
Note
Always broadcasted.
X0 50 FF
88 01 00 01 FF
VISCA Interface and Inquiry
● CAM_VersionInq
Returns information on the VISCA interface.
Inquiry
Inquiry Packet Reply Packet
CAM_VersionInq
8X 09 00 02 FF Y0 50 GG GG
HH HH JJ JJ
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)
Command List
Description
GGGG = Vender ID
(0020: Sony)
KK FF
HHHH = Model ID
0434 = FCB-EX480C
0435 = FCB-EX480CP
0436 = FCB-EX48C
0437 = FCB-EX48CP
JJJJ = ROM revision
KK = Maximum socket # (02)