Trouble shooting

Symptom
Power
Indicator [E] not
illuminated
18
ProDaylight Air
is not turned
on when On/
Off Button [D]
is pressed and
"LAMP" is
shown in the
Display [F].
ProDaylight
Air turns off
automatically
and "HOT" is
shown in the
Display [F].
www.profoto.com
Diagnose
Bad connection to the
ballast or AC mains.
Internal fuse defect.
A safety switch prevents
the lamp from being
turned on if the glass cover
is not in place.
The unit is overheated.
Action
• Check that the Lamp Cable [3] and
the AC mains cable are correctly
connected.
• Check the fuses on the ProBallast
200/400. If the problem remains
after replacing the fuses, contact
your nearest Profoto service
station.
Fit the glass cover correctly in place,
see instructions on page 13.
• Ensure better ventilation.
• Wait until the temperature
decreases before the unit is
turned on again.
• If the problem remains please
contact your nearest Profoto
service station.