operating instructions

Stand mounting

1. Mount and fasten the ProDaylight Air unit on the stand using the locking knob on the
Stand Adapter [4].
2. The unit can be directed upwards/downwards when the Locking Handle [5] is
loosened. Fasten the Locking Handle [5] when the unit is correctly directed.
For alternative ways of mounting, the ProDaylight Air unit can be removed from the bracket
by unscrewing the 5 mm hex socket Bracket Screw [2].

remove protecting cap

1. Unlock the clasp on the protecting cap.
2. Gently remove the protecting cap from the ProDaylight Air unit.

changing glass cover

iii
1. Ensure that the ProDaylight Air unit is turned off and that the Lamp Cable [3] is not
connected.
2. If the ProDaylight Air unit has been in use, wait for the unit to cool down or use protective
gloves.
3. Unlock the glass cover by pressing down the safety pins [i] and then pulling them out
one by one.
4. Gently remove the glass cover and fit the new glass cover in place.
5. Make sure that the safety switch [ii] is pressed down and that both safety pins fit
properly into the slots [iii] on each side of the glass cover.
6. Secure the glass cover by pressing the safety pins down and then pushing them one
by one under the top screw.