B.7 Timing Settings
Timepulse (UBX – CFG – TP)
Parameter
Pulse Mode
Pulse Period
Pulse Length
Time Source
Cable Delay
User Delay
Table 51: Timepulse default settings
C Reference Design for TIM-4R
For a Reference Design for the TIM-4R including design, reference schematic, bill of material and a reference
layout please consult the Application Note: Reference Design for TIM-4R [6].
17
The Number entered under Target1 – Target2 defines the output cycle: 1 means every measurement cycle, 2 every 2
LEA-4R / TIM-4R - System Integration Manual / Reference Design
GPS.G4-MS4-05043
Type
USART1
USART2
17
(TARGET1
)
(TARGET2 )
Out
1
Out
1
Out
1
Out
Out
Out
1
Default setting
unit
+1 - rising
1000
ms
100
ms
1 – GPS time
50
ns