2 Powering the ERX 350
2 Powering the ERX 350
2.1 Battery Power Units
The Connections are made at P5 connector on the ERX 350 I/O Board. The ERX 350 unit can be operated
from the following battery power:
40-6050 (4-cell Alkaline) – 5 year operating life under specified conditions
40-6048 (2-cell Lithium)
Dual set of 40-6048 (2-cell Lithium) – extended life or heavy usage / comms applications.
Item 1061 (Battery Type) is used to select the type of battery pack that is to power the instrument.    Verify
item 1061 is correctly configured for the installed battery pack.
0 = 4 D-Cell Alkaline Receptacle Pack, for EC350 only - Default
1 = 2 D-Cell Lithium Sealed Pack, for EC350 only
2 = Dual 2 D-Cell Lithium Sealed Packs (connected in parallel), for EC350 only