Service Information

Gas Spring

Required Tools: #3 Philips Screwdriver; Slotted (Flat) Screwdriver; 5/8 Socket or Wrench
1. Remove the release handle by prying out the retaining clip and removing the handle support pin.
2. Remove the nut holding the top end of gas spring to the support bracket.
3. Remove four screws from the support bracket and lift off the support bracket.
4. Pry out the retaining clip close to the bottom of the inner column and pull out the gas spring support
pin (this may require moving the gas spring from the top edge).
5. Remove gas spring assembly from the inner column.
6. Reverse to install the new gas spring.
NOTE: When reinstalling, the new gas spring will need to be compressed slightly in order to fasten
the support bracket to the outer column by means of the four screws pertaining to step 3.

Outer Column Replacement

Required Tools: #2 Philips Screwdriver
1. Remove the primary top.
2. Slide the column all the way down and remove the locking screw on the inner column.
3. Now remove the outer column cap by removing four screws.
4. Pull the outer column away from the base.
5. Remove the glides from the inside of the column.
6. Reverse to install a new outer column.

Caster Replacement

Required Tools: 13 mm wrench
1. Fully raise the table top.
2. While maintaining a secure grip on the table, carefully flip it over or turn it on its side to allow access
to the damaged caster.
3. Use the 13 mm wrench to remove the damaged casters and replace with new casters.