Inputs/Outputs:

Push Buttons

Notes:
- Connecting terminals COM to ACT1 will activate the operator to open
- Push buttons, card readers etc will all wire the same
- Multiple inputs can be wired together
- Use 20 gauge wire
Strike
Notes:
- use terminals LOCK & +24 to signal
strike
- use 20 gauge wire

Programming Functions

1. overload
2. activation delay
3. back check
4. holding time
5. opening speed
6. closing speed
7. latching speed
8. hold open
9. power assist
10. reactivation
O M E G A
Range
50-99
0-99
0-99
0-99
10-70
0-99
0-99
0-1
0-1
0-1
A U T O M A T I C S
Units Default
%
0.1seconds
%
1.0 seconds
%
%
%
on/off
on/off
on/off
2 0 1 8
V 2 . 0
50
0
20
15
50
20
5
0
0
0