    PRESENTATION OF THE APPLIANCE Lacunza congratulates you on your choice. Certified under ISO 9001, Lacunza guarantees the quality of its appliances and undertakes to meet the needs of its customers. Confident of the know-how afforded by more than 50 years’ experience, Lacunza uses advanced technologies in the design and manufacture of its entire range of appliances.
  • Page 3 PRESENTATION OF THE APPLIANCE MAINTENANCE AND IMPORTANT ADVICE ..................20 4.1. Maintenance of the appliance ........................20 4.1.1. Firebox ................................... 20 4.1.2. Flue socket ................................20 4.1.3. Painted sheet-steel-cast-iron parts........................20 4.1.4. Firebox glass ................................20 4.1.5. Electrical system ..............................20 4.1.6.
  • Page 4: Presentation Of The Appliance

    1.1. General characteristics Unit IV-800 Nominal Heat Output (N.H.O.) to atmosphere Efficiency at N.H.O. CO emission at 13% O2 at N.H.O.
  • Page 5: Presentation Of The Appliance

    Instruction Book. Failure to respect these conditions may lead to problems with the appliance (deterioration, shorter useful life, etc.) which are not covered by the Lacunza warranty. Figure No.1 - Dimensions of the IV-800 in mm...
  • Page 6: Instructions For The Installer

    P ≤ 10kW fixtures, etc.). 10 < P ≤ 15 Lacunza’s liability is limited to the 15 < P ≤ 20 supply of the material and does not include 20 < P ≤ 25 installation of the appliance.
  • Page 7: Location Of The Appliance In The Room

    INSTRUCTIONS FOR THE INSTALLER 2.2.2. Location of the appliance in the Bear in mind that it may even be room necessary to protect non-combustible material in order to prevent breakage, Choose a location in the room which deformation, etc., result favours good hot-air distribution by overheating non-combustible...
  • Page 8: Casing

    INSTRUCTIONS FOR THE INSTALLER 2.3.5. Casing Figure No.5 - Interior diagram of the casing The image below gives an example of how the appliance can be encased Key to casing diagram: properly: 1 Ceiling 2 Flue 3 Incombustible material (Inner hood insulation) 4 Insulating deflector made of incombustible material...
  • Page 9: Connection To The Flue

    100 cm2 for the following points in mind. the intake of air for combustion. • The air ducts must always be heat non-central-heating appliances insulated and smooth inside (not (without back boiler), Lacunza does not corrugated).
  • Page 10 Nominal Heat Output: Output (kW) IV-800 Note: The values shown in the above table were measured at the appliance output point and based on tests performed at nominal heat output and maximum fan speed.
  • Page 11: Exterior Frame. Assembly

    2.3.8. Exterior Frame. Assembly the door or to screw anything on. For clients that are interested, Lacunza has a 4 external sided frame for the IF-800 and IV-800 apparatus. There are various possibilities when it comes to positioning the frame, depending on the fitter’s preferences:...
  • Page 12: Turbine-Potentiometer Connection

    Figure No.14 - Connections to be carried out in the potentiometer building, the heat of the gases serving to heat rooms, insulating only those sections where excess temperature may cause WARNING: the operating temperature damage. of the potentiometer supplied by Lacunza...
  • Page 13: Chimney Crown

    INSTRUCTIONS FOR THE INSTALLER If the chimney is constructed, then it is It must be possible to clean the entire necessary to pipe and insulate it to ensure flue, no sections being left inaccessible for correct updraught. cleaning purposes. The diameter of the pipe must be the 2.4.2.
  • Page 14 INSTRUCTIONS FOR THE INSTALLER Figure No.15 - Distances between chimney Figure No.17 - Distances between the chimney crown and objects within a radius crown and roof ridge of between 10 and 20m The chimney crown must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m.
  • Page 15: Instructions Of Use

    INSTRUCTIONS OF USE • Resinous wood may mean that the INSTRUCTIONS OF USE appliance and the flue need to be cleaned more often. The manufacturer accepts no liability whatsoever for damage caused to parts as Non-permitted fuels: a result of the improper use of non- •...
  • Page 16: Description Of The Parts Of The Appliance

    INSTRUCTIONS OF USE 3.2. Description of the parts of the appliance 3.2.1. Operating components Figure No.19 - Operating components on the appliance • A: Firebox door handle • B: Primary air intake: open to the right • C: Secondary air intake: open to the right Proceed as follows in order to light the appliance satisfactorily: 3.3.
  • Page 17: Loading Fuel

    INSTRUCTIONS OF USE • Leave the door slightly ajar, the Be careful when placing logs in the firebox width of two or three fingers, for about on appliances with vermiculite interiors. 15 minutes until the glass warms up. Vermiculite is a fragile material and may •...
  • Page 18: Removing Ash

    INSTRUCTIONS OF USE recommend you close the Primary Intake and leave the Secondary 15mm open. Figure No.2 - Removing the separator Figure No.20 - Secondary-air intake 15 mm open 3.6. Removing ash After the continuous use of the apparatus, it is essential to extract the ashes from the firebox.
  • Page 19: Cooking Grille

    INSTRUCTIONS OF USE Figure No.5 - Cooking grille in position The cooking grille is an element to be used intermittently. The grille is not designed to work non-stop over the fire. Never close the door with the handles inside the firebox. These handles should only be used when the grille is being moved.
  • Page 20: Electrical System

    INSTRUCTIONS OF USE Finally, the vermiculite deflectors can then be extracted as shown: Figure No.7 - Extracting the vermiculite deflectors 3.9. Electrical system Forced convetion. Fans This model has two fans for the forced convection of the hot air generated around the appliance inside the shell.
  • Page 21: Maintenance And Important Advice

    MAINTENANCE AND IMPORTANT ADVICE the installation and use), so as to avoid the MAINTENANCE AND accumulation of ash, lint and other remains IMPORTANT ADVICE that may generate strange noises and/or deteriorate the ventilators and electrical system. Disconnect the electrical network 4.1.
  • Page 22: Important Advice

    MAINTENANCE AND IMPORTANT ADVICE the appliance is used often, then the Lacunza accepts no liability for any chimney and the flue connector piping modification to the product which it has must be swept several times a year. not authorised. In the event of fire in the chimney, close...
  • Page 23: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING This symbol means that a qualified professional should be called to perform the operation. Problem Probable causes Solution Use hard woods, cut at least 2 years ago and stored in a Green or damp wood sheltered, ventilated place Use crumpled paper or firelighters and dry wood chips to light The logs are too large the fire.
  • Page 24: Basic Breakdowns

    Pieza móvil registro primario IF-800 504420000012 Pieza móvil registro secundario IF-800 509020000042 Cordón Negro Ø13mm 500000000510 Cordon plano pelos 8x2mm 504430000000 Vermiculita lateral izda delantera IV-800 504430000001 Vermiculita lateral trasera IV-800 5044400002 Vermiculita trasera central IV-800 504430000003 Vermiculita lateral dcha delantera IV-800 5044400003...
  • Page 25: Declaration Of Performance

    DECLARATION OF PERFORMANCE DECLARATION OF PERFORMANCE...
  • Page 26 DECLARATION OF PERFORMANCE...
  • Page 27: Ce Mark

    CE MARK CE MARK...
  • Page 28 LACUNZA KALOR GROUP S.A.L Pol. Ind. Ibarrea s/n 31800 Alsasua (Navarra) Spain Tel.: (00 34) 948 56 35 11 Fax.: (00 34) 948 56 35 05 e-mail: comercial@lacunza.net Website: www.lacunza.net EDITION: 0...