6.3 Setting the timer operating mode

1. Press [MODE] to scroll to the desired
operating mode. See below for a description
of each mode.
– "ON": Manual ON mode is selected. The
device will stay ON.
– "AUTO ON": Automatic mode is selected
and the device is ON. The device will stay
ON until the next OFF event.
– "RDM ON": Random mode is selected and
the device is ON. The device will stay ON
until the next OFF event.
NOTE: When "RDM" (random mode) is
selected, the device will operate ± 30
minutes from the scheduled ON/OFF
event settings to provide a lived-in look.
– "OFF": Manual OFF mode is selected. The
device will stay OFF.
– "AUTO OFF": Automatic mode is selected
and the device is OFF. The device will
stay OFF until the next ON event.
– "RDM OFF": Random mode is selected
and the device is OFF. The device will
stay OFF until the next ON event.
2. Plug the pump into the timer.
3. Plug the timer into the electrical outlet.

7. Technical data

Ratings:
125 VAC, 60 Hz, 15 A, 1875
W resistive
8 A, 1000 W tungsten, 500
Supply voltage
VA electronic ballast
120 VAC, 60 Hz, 8.3 A
standard ballast
1/2 HP motor load
Contact rating
15 amps

8. Disposing of the product

This product or parts of it must be disposed of in
an environmentally sound way:
1. Use the public or private waste collection
service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.