FRONT PANEL ......................... 6 REAR PANEL ........................... 9 INSTALLATION ......................... 9 RECOMMENDED WIRING ....................... 9 TURNING PG 600 S ON WITH NO GRID POWER ............... 15 TURNING PG 600 S OFF ....................... 15 OPERATION MODES ......................15 SETTINGS ..........................16 POSSIBLE FAULTS, TROUBLESHOOTING ................
The appliance may be installed by authorized staff only! When switching off the electric appliance fed by PG 600 S do not forget to switch off the PG 600 S itself as well. Otherwise the its inverter continues to supply electricity from its battery and does not switch off until the battery voltage drops below the set min.
TAKING CARE OF YOUR BATTERY The appliance is equipped with maintenance-free lead acid batteries. The following rules shall be respected when using them: Avoid any mechanical stress, especially by a hit. Avoid any damage to the battery casing and do not attempt to open it. The acid inside is toxic, dangerous to skin and eyes! In no case shall the battery be exposed to high temperatures or flames.
- PG 600 line UPS is intended preferably for circulation pumps in heating systems. - The PG 600 S load shall not exceed the value shown on the label placed on its rear panel. - Use rechargeable lead acid batteries only, supplied by Regulus, designed for backup power supplies.
1.2 FRONT PANEL 1. ON push button 10. select 2. OFF push button 11. confirm 3. display 4. by-pass indicator 5. input AC voltage indicator 6. battery indicator 7. output AC voltage indicator 8. error indicator 9. back Visual indicators and sound alarms The front panel is fitted with 5 LED indicators.
Page 7
Display info The information to be shown can be retrieved by repeated pressing the Select key. The displayed information is presented in the table below. Optional info Display Imput Input voltage = 230 V, input frequency = 50 Hz Battery Battery voltage = 24,8 V, battery current = 1 A Output Output voltage = 230 V, output frequency = 50 Hz...
Page 8
LCD Display Display Function Battery info in AC mode: Charging condition is shown. Condition Battery voltage Display Constant current 0%-25% All bars gradually blink. / constant volt- 25%-50% The bottom bar is lit and the remaining three gradually blink. age mode: 25%-50% The bottom two bars are lit and the remaining two gradually blink.
TN-S wiring system. 6. Press and hold ON push button for 2 sec. to turn on PG 600 S. An audio signal will sound. The green LED will stay lit, indicating that PG 600 S is running (standard mode, ready for backup).
Page 10
IR12 CTC controller Backup of circulation pump of a heat pump. PG 600 S BACKUP POWER SUPPLY PUMP WITH BACKUP MAINS BATTERY 230 V, 50 Hz IR 12 SMART CONTROLLER CIRCUIT WITH CIRCUIT WITHOUT BACKUP BACKUP PUMP WITHOUT BACKUP Do respect the separation between the circuits with and without backup.
Page 11
IR12 CTC controller + fireplace module Backup of circulation pump of a fireplace. PG 600 S BACKUP POWER SUPPLY PUMP WITH BACKUP MAINS BATTERY 230 V, 50 Hz IR 12 SMART CIRCUIT WITHOUT CIRCUIT WITH CONTROLLER BACKUP BACKUP PUMP WITHOUT BACKUP Do respect the separation between the circuits with and without backup.
Page 12
IR12 CTC controller + PWM module Backup of a PWM-controlled solar pump. PG 600 S BACKUP POWER SUPPLY PUMP WITH BACKUP MAINS BATTERY 230 V, 50 Hz IR 12 SMART CONTROLLER CIRCUIT WITHOUT CIRCUIT WITH BACKUP BACKUP PUMP WITHOUT BACKUP Do respect the separation between the circuits with and without backup.
Page 13
Fireplace Backup of a fireplace circulation pump with flue thermostat. FLUE THERMOSTAT PG 600 S BACKUP POWER SUPPLY PUMP WITH BACKUP MAINS BATTERY 230 V, 50 Hz...
Page 14
STDC, TRS etc. controller Pump backup PG 600 S BACKUP POWER SUPPLY ZÁLOHOVANÉ PUMP WITH BACKUP ČERPADLO MAINS BATTERY 230 V, 50 Hz STDC, TRS etc. controller STDC, TRS etc. controller Backup of a PWM-controlled pump. PG 600 S BACKUP POWER SUPPLY ZÁLOHOVANÉ...
2.3 TURNING PG 600 S OFF PG 600 S can be turned off by pressing and holding the OFF push button for at least 3 sec. The display will go off. WARNING! The battery is not being charged. It will not backup anything in case of a power supply failure, however as soon as the power supply is restored, it will switch on.
4 SETTINGS The settings mode can be entered by pressing and holding the Confirm key for 2 sec. The settings programs can be selected by pressing the Confirm key. A parameter can be changed by pressing the Select key. By pressing and holding the Back key for 2 sec. you will leave the settings mode. All changes will be applied after the device restart.
5 POSSIBLE FAULTS, TROUBLESHOOTING Error Fault POSSIBLE FAULTS, TROUBLESHOOTING code Too high temperature Too high battery voltage Too low battery voltage Short-circuited output Too high output voltage from the UPS Overload Main relay faulty Too low input voltage Too high input voltage Too low input frequency Too high input frequency Automatic voltage regulator faulty...
Page 18
TROUBLESHOOTING If the UPS went to Fault mode, turn off the power supply. Find the fault and its solution in the table below. If you do not understand the fault or cannot remove it, switch off the UPS and contact a service provider.
6 TECHNICAL DATA Codes 17135 PG 600 S Backup Power Supply with 18 Ah external battery 17136 PG 600 S Backup Power Supply with 44 Ah external battery 17137 PG 600 S Backup Power Supply with 100 Ah external battery...