Table of Contents APPLICABLE MODEL(S) ................................IV REVISION HISTORY TABLE ................................ IV GENERAL INFORMATION ................................1 Purpose of this Manual ..............................1 Intended Use ..................................1 Training Options ................................. 1 Symbols and Warnings ............................... 2 Safety Instructions ................................4 Electromagnetic Interference ............................5 Electromagnetic Compatibility (EMC) ..........................
User Manual | MTI 830 & 829 APPLICABLE MODEL(S) This manual is for the following product numbers and serial numbers: PRODUCT NUMBER DESCRIPTION EFFECTIVE S/N 830-001-XX 830 Procedure Chair, Std Base, 100-240V 181016-XXXX to Current 830-002-XX 830 Procedure Chair, Swivel Base, 100-240V...
Training is accomplished either through reading the installation and operation sections of the user manual or through remote training provided by MTI Customer Service. To request training, contact MTI. PRODUCT INFORMATION Date of Purchase:...
User Manual | MTI 830 & 829 Symbols and Warnings Type B applied part This manual contains Notices, Cautions, and Warnings, which Type B, partie appliquée are meant to call attention to particular parts or sections Proper shipping orientation for the product of this manual.
Page 7
Upper and lower limits of relative humidity Steering Mode (green) Limites haute et basse de humidité relative Mode de Direction (vert) Free Mode (yellow) Upper and lower limits of atmospheric pressure Mode Libre (jaune) Limites haute et basse de la pression atmosphérique Locked Mode (red) Mode verrouillé...
Assurer l’appareil, patient, et d’autre objets sont dans un état sûr avant d’utiliser l’appareil. Backrest, seat, footrest, armrest, headrest, and other parts of the equipment should only be used for their intended purpose. MTI is WARNING/AVERTISSEMENT not responsible for use of components outside of their intended Verify patient arms, headrest and other adjustable equipment use.
éviter tout risque de dégradation des www.mti.net/faqs for details on California Proposition 65. performances de cet équipement. Ce produit peut vous exposer à des agents chimiques, y compris WARNING/AVERTISSEMENT le nickel, identifiés par l’État de Californie comme pouvant causer...
Page 10
The MTI Procedure Chair is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the MTI Procedure Chair can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MTI Procedure Chair as recommended below, according to the maximum output power of the communications equipment.
Page 11
RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the MTI Procedure Chair is used exceeds the applicable RF compliance level above, the MTI Procedure Chair should be observed to verify normal operation.
GUIDANCE AND MANUFACTURER’S DECLARATION - ELECTROMAGNETIC IMMUNITY The MTI Procedure Chair is intended for use in the electromagnetic environment specified below. The customer or the user of the MTI Procedure Chair should assure that it is used in such an environment.
brûlures pour le patient. Le cordon d’alimentation peut être utilisé pour isoler simultanément les deux pôles de l’alimentation en retirant le cordon d’alimentation WARNING/AVERTISSEMENT à l’entrée de l’équipement ou la prise murale. Connecting electrical equipment to multiple socket-outlet effectively leads to creating a medical electronic system and can result in a Contraindications reduced level of safety.
The 830 Series Procedure Chairs have power lift, back, tilt, foot, and foot extension functions. The 830 Series Chairs have a 725 lb. (328.8 kg) patient capacity. The 830 Series Chairs are 25” (63.5 cm) wide with an entry height of 18 3/4” (47.6 cm). The 830 Series Chairs are available in 3 different base configurations: Standard Base, Swivel Base, and Mobile Base.
Page 15
830/829 SWIVEL BASE CHAIR Headrest Angle Adjustment Knob Headrest Headrest Height Adjustment Knob Back Spline Location (optional) Backrest Back Accessory Mount Location Seat Floating Arm Spline Rear Seat Spline Location (optional) Front Seat Spline Location (optional) Footrest Serial Number Label...
User Manual | MTI 830 & 829 INSTALLATION NOTICE/AVIS If this product has been exposed to low temperatures, allow WARNING/AVERTISSEMENT adequate time for it to warm to room temperature before This equipment is heavy, get help to remove it from the shipping putting it into service.
Unpacking and Set-up 1. Remove shipping straps, 2. (Standard/Swivel Base) 3. If the chair has 2” Leveling Glide, 4. With the back and seat shipping box, and other boxes Remove (4) shipping bolts with Duplex Outlet, Slant Mount, or sections of the chair in the flat from the pallet.
Maximum surface temperature of applied part chair surfaces will not exceed 42°C. SmartTech™ SmartTech™ is the combination of MTI’s Smart Controller™ and Smart Safety™ technology using a centralized computer controller that enhances safety, reduces energy consumption, and provides smoother movement, additional memory options, and more user preferences.
Home Button and Program Buttons Settings Momentary Button Setting This setting is the factory default setting for the Home Button and Program Buttons. It allows the user to press and release the Home Button or Program Buttons to automatically move the chair to the button’s saved position.
User Manual | MTI 830 & 829 To enable the Safety Lockout, press the following sequence of buttons (within 1 second between presses): Stop, Stop, Back Up, Stop. If a swivel model chair is unlocked when Safety Lockout is enabled, the swivel will automatically lock and remain locked, even upon disabling the Safety Lockout.
Page 21
Program Buttons The Program Buttons move the chair to a user defined Program Position. NOTE: The chair has no pre-existing Program Positions upon arrival and will only beep and not move until Program Positions (P1, P2, P3, P4) have been saved. The Program Buttons have two button settings that can be changed by the user.
User Manual | MTI 830 & 829 Headrest Operation Articulating Headrests 1. To attach the headrest. 2. To adjust the height of the 3. To adjust the angle of the 4. To remove a headrest: headrest: headrest: A. Loosen the knob on the A.
Swivel Base Operation For Swivel Base model only, use the following instructions to learn how to operate the swivel base and the two user preference settings. The Swivel Base model has two Swivel Button settings for user preference. To change the setting, see “To enter the Smart Controller™...
Page 24
User Manual | MTI 830 & 829 MODE INDICATOR: Each locking bar has a mode indicator line on the center of the pedal that points to the adjacent indicator label on the base of the chair. Note that the (3) Total Lock Casters operate the same whether they are in FREE or STEER Mode.
Accessory Mount, Base Provides a base mount for Mayo Trays, IV Rods, Lights, and Cardiac Monitor Trays. Accessory Mtg Rail Assy, 829 Seat & 830 Provides standard hospital rails to attach to Requires Spline Assy, A Size (set of 2)
Page 26
830 Series Procedure Chairs. Spline Assy, B Size (set of 2) Provides 2 splines to mount in the Rear Seat Only used on 830 Procedure Chair in Rear location. Seat Spline Location. Stirrups, Seat Spline Mtd (pair) Used to position patient’s legs during...
Page 27
Requires Spline Assy, A Size (Set of 2) for 829 Series Procedure Chairs mounted in Rear Seat Spline Location. Requires Spline Assy, B Size (Set of 2) for 830 Series Procedure Chairs mounted in Rear Seat Spline Location. Vision Block, Seat Spline Mtd...
Policy” for more details on disinfecting solutions which have Contact with sharp or pointed objects can damage the been tested on MTI’s products. It is available for download at upholstery. Do not place hard surface objects on the upholstery www.mti.net/DisinfectantsPolicy. In the U.S. & Canada, call...
3. All mechanical functions should operate properly. the serial number tag. Have an authorized service technician inspect your equipment If service is required, contact MTI. once a year. U.S. & Canada (888) 520-4998 Power Cord Removal Instructions...
This warranty does not apply to any part or product which upon examination by MTI or its authorized agents indicates the product has been repaired or altered in any way by persons other than MTI or its authorized agents, has been misused, abused or used in a manner contrary to any instructions issued by MTI.
Voir «GUIDE TO INDICATOR LIGHTS AND SOUNDS» à la page 29 pour des solutions supplémentaires. Pour plus d’informations sur cet équipement, y compris des schémas de circuits, les manuels de service et pièces, et autres descriptions, s’il vous plaît contacter MTI.
Page 32
Voir «GUIDE TO INDICATOR LIGHTS AND SOUNDS» à la page 29 pour des solutions supplémentaires. Pour plus d’informations sur cet équipement, y compris des schémas de circuits, les manuels de service et pièces, et autres descriptions, s’il vous plaît contacter MTI.
GUIDE TO INDICATOR LIGHTS AND SOUNDS LIGHTS SOUND STATUS OR CONDITION GREEN BLUE ORANGE Start Up Tune Chair has been plugged in. Solid None Chair is in hibernation state to conserve power. To Slow Flash exit hibernation press any button. None Chair is moving to the Programmed Home or a Rapid...
Page 34
User Manual | MTI 830 & 829 GUIDE TO INDICATOR LIGHTS AND SOUNDS LIGHTS SOUND STATUS OR CONDITION GREEN BLUE ORANGE Low Beep Stop Button has been pressed for 5 seconds Flash Flash Solid awaiting sequence to enter Smart Controller™...
829 Plush Upholstery Kit 28 lb (12.7 kg) Table Top Range 830/829 Standard Base 18.75-39 in (47.6-99 cm) 830/829 Swivel Base and Mobile Base 18.75-37 in (47.6-94 cm) Back Section Range 0°± 2.2° (horizontal) to 85°± 2.2° Table Top Tilt Range 0°...
Page 36
User Manual | MTI 830 & 829 SPECIFICATIONS DESCRIPTION SPECIFICATION Power Cord Plugs: U.S.A. standard 3 prong and IEC 60320-C13 (self-retaining) Electrical Ratings 100-240VAC (47-63 Hz); 7 Amps Fuse Replacement (2) 5mm x 20mm 4 Amp 250V Time-Delay Glass Tube Fuse...
Need help?
Do you have a question about the 830 and is the answer not in the manual?
Questions and answers