TH-50PHD3 / TH-50PHW3
5.9.
Sub brighness setting
INPUT
1 NTSC
Gray Scale
Pattern
Black 2 %
Black 0 %
2 PAL
Gray Scale
Pattern
Black 2 %
Black 0 %
SECAM
Gray Scale
Pattern
3 PC
Gray Scale
Pattern
Black 2 %
Black 0 %
RGB
Gray Scale
Pattern
Equipment
Setting
Picture:
PANEL W/B
Normal
Aspect:
16:9
Picture:
PANEL W/B
Normal
Aspect:
16:9
Picture:
PANEL W/B
Normal
Aspect:
16:9
Alignment menu
** Adjust at the dark room.
All cut off 1) Set white balance to Cool .
2) Adjust All cut off to start some pixels emission
at black 2% area and no emission at black 0% area.
3) Write down all cut off data.
4) Set white balance to Nornal .
5) Adjust All cut off to set same data of Cool mode.
6) Set white balance to warm .
7) Adjust All cut off to set same data of Cool mode.
** Adjust at the dark room.
All cut off 1) Set white balance to Cool .
2) Adjust All cut off to start some pixels emission
at black 2% area and no emission at black 0% area.
3) Write down all cut off data.
4) Set white balance to Nornal .
5) Adjust All cut off to set same data of Cool mode.
6) Set white balance to warm .
7) Adjust All cut off to set same data of Cool mode.
8) Change to SECAM signal.
9) Copy PAL All cut off data to SECAM mode.
** Adjust at the dark room.
All cut off 1) Set white balance to Cool .
2) Adjust All cut off to start some pixels emission
at black 2% area and no emission at black 0% area.
3) Write down all cut off data.
4) Set white balance to Nornal .
5) Adjust All cut off to set same data of Cool mode.
6) Set white balance to warm .
7) Adjust All cut off to set same data of Cool mode.
8) Change to RGB input signal.
9) Copy PAL All cut off data to SECAM mode.
26
Procedure