Table 2: Single Zone Wall Mounted Extended Piping Specifications.
System (Model) (Indoor Unit / Outdoor Unit)
Cooling Capacity
(Min/Rated/Max) (Btu/h)
1
Cooling Power Input
(Rated) (kW)
1
Heating Capacity (Min/Rated/Max) (Btu/h)
Heating Power Input
(Rated) (kW)
1
COP
Maximum Heating Capacity (Btu/h)
Outdoor 17°F (WB)/Indoor 70°F (DB)
Outdoor 5°F (WB)/Indoor 70°F (DB)
Outdoor 0°F (WB)/Indoor 70°F (DB)
Outdoor -4°F (WB)/Indoor 70°F (DB)
EER
SEER
HSPF
Power Supply V, Ø, Hz
2
Outdoor Unit Operating Range
Cooling (°F DB)
Heating (°F WB)
Indoor Unit Operating Range
2
Cooling (°F WB)
Heating (°F DB)
Unit Data
Refrigerant Type
3
Refrigerant Control
IDU Sound Pressure Level dB(A) (H/M/L/SL)
ODU Sound Pressure Level dB(A)
Unit Weight (lbs.)
IDU (Net/Shipping)
ODU (Net/Shipping)
Power Wiring / Communications Cable (No. x AWG)
Compressor
Compressor (Qty.)
Fan
IDU Type x Qty.
ODU Type x Qty.
Motor / Drive
Airflow Rate
IDU (H / M / L [CFM])
ODU (Max. [CFM])
Piping
Liquid (in.)
Vapor (in.)
Condensate Drain O.D. / I.D. (in.)
Additional Refrigerant Charge (oz./ft.)
Pipe Length
(Minimum/ Maximum) (ft.)
5
Piping Length
(no add'l refrigerant, ft.)
5
Max. Elevation Difference (ft.)
EEV: Electronic Expansion Valve
IDU: Indoor Unit
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
This unit comes with a dry helium charge.
Power wiring to the ODU is field supplied, solid or stranded, and must comply with the applicable local
and national codes
Single Zone Wall Mounted Extended Piping Specifications
2
4
4
2
ODU: Outdoor Unit
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
LS243HLV
(LSN243HLV/LSU243HLV)
(LSN303HLV/LSU303HLV)
3,070 ~ 22,000 ~ 29,515
3,070 ~ 30,000 ~ 34,000
1.76
3,070 ~ 27,000 ~ 38,898
3,070 ~ 32,000 ~ 38,898
2.38
11.34
27,410 (102%)
23,690 (88%)
22,090 (82%)
20,580 (76%)
12.50
21.50
11.0
49/44/40/37
55
39.7/45.2
124.6/132.3
4 x 18
Twin Rotary (1)
Brushless Digitally Controlled/Direct
953/848/706/530
2,119
3/8
5/8
27/32 / 5/8
0.38
9.8/164
24.6
98.4
Power Input is rated at high speed.
1
Low Ambient Wind Baffle Kit allows operation down to 0°F in cooling mode.
2
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
3
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
5
comply with applicable and national code.
Piping lengths are equivalent.
6

GENERAL DATA

LS303HLV
(LSN363HLV/LSU363HLV)
3,070 ~ 33,000 ~ 34,000
3.0
3,070 ~ 35,200 ~ 38,898
3.1
10.32
32,490 (102%)
35,740 (102%)
28,080 (88%)
26,180 (82%)
24,390 (76%)
10.00
19.00
10.0
208-230/60/1
14 to 118
-4 to +65
53 to 75
60 to 86
R410A
EEV
49/44/40/37
55
39.7/45.2
124.6/132.3
4 x 18
Twin Rotary (1)
Twin Rotary (1)
Cross Flow Fan (1)
Propeller (1)
953/848/706/530
953/848/706/530
2,119
3/8
5/8
27/32 / 5/8
0.38
9.8/164
24.6
98.4
PRODUCT DATA | 11
LS363HLV
4.04
3.84
9.17
30,890 (88%)
28,800 (82%)
26,820 (76%)
8.18
17.50
10.0
49/44/40/37
55
39.7/45.2
124.6/132.3
4 x 18
2,119
3/8
5/8
27/32 / 5/8
0.38
9.8/164
24.6
98.4