Models 50X & 75X Electric Pressure Steam Sterilizers
50X shown with optional support base, Part No. 2180
CAUTION! READ THESE IMPORTANT SAFEGUARDS!
FAILURE TO FOLLOW INSTRUCTIONS AND/OR
IMPROPER USE MAY RESULT IN SCALDING,
BODILY INJURIES OR EXPLOSION.
When using the pressure steam sterilizer, basic
safety precautions should always be followed:
1. Read and understand instruction manual before
operating unit.
2. Do not touch hot surfaces. Use handles and pot
holders.
3. Close supervision is necessary when the
sterilizer is used near children.
4. Extreme caution must be used when moving a
sterilizer containing hot liquids.
5. Do not use the sterilizer for other than intended
use.
6. Always check the pressure release devices for
02/09 - 2M
OPERATING INSTRUCTIONS
clogging before use.
7. This sterilizer operates under pressure. Improper
use may result in scalding injury. Make certain
unit is properly closed before operating. Read
Operating Instructions.
8. Never loosen wing nuts until the steam pressure
gauge registers zero and you have allowed any
remaining pressure to escape by opening the
control valve (toggle in the vertical position).
9. Do not open the sterilizer until the unit has
cooled and internal pressure has been reduced.
Gauge should read zero at this time. Read
Operating Instructions.
10. Never use the sterilizer for cooking or
processing food.
11. Never place oil in or on this sterilizer.
75X shown with optional support base, Part No. 4180
12. Do not subject your sterilizer to sudden extreme
temperature changes, as this will cause
expansion or contraction which can crack a cast
aluminum utensil. Do not move a sterilizer from a
cold storage area directly onto a hot flame or
element. Do not add cold water to a sterilizer
which has boiled dry and is still hot. Do not cool
the sterilizer suddenly by pouring cold water on it
or wrapping cold wet towels around it.
13. Always operate sterilizers on surfaces that will
not be damaged by heat. We recommend the use
of our support base. See page 5, item 6.
14. As in all clinical laboratory settings, wear safety
glasses when attending to your sterilizer.
SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 50X Series and is the answer not in the manual?

Questions and answers

Summary of Contents for All American 50X Series

  • Page 1 OPERATING INSTRUCTIONS Models 50X & 75X Electric Pressure Steam Sterilizers 50X shown with optional support base, Part No. 2180 75X shown with optional support base, Part No. 4180 CAUTION! READ THESE IMPORTANT SAFEGUARDS! FAILURE TO FOLLOW INSTRUCTIONS AND/OR clogging before use. 12.
  • Page 2 Operating Instructions for Model 50X/75X Electric Pressure Steam Sterilizer IMPORTANT: DO NOT OPERATE THIS PRESSURE STEAM STERILIZER UNTIL YOU HAVE THOROUGHLY READ THESE OPERATING INSTRUCTIONS. Cleaning Overpressure Plug #1010 Excess Pressure Relief Valve Geared Steam Gauge When you are done using your sterilizer, you #2050CS # 72S need to empty the water from the unit, rinse...
  • Page 3 Bakelite Top Handle Control Valve Geared Steam Gauge # 72S Overpressure Excess Pressure Plug #1010 Relief Valve #2050CS Air Exhaust Tube #2155-25(50X)/#2155-41(75X) Aluminum Inner Container #2156(50X)/#4156(75X) Side Handle #405(75X Only) Rack #111(50X)/#151(75X) Support Stand #2151(50X)/#4151(75X) NOTE: Opening fits over heating elements.
  • Page 4 OPERATION If the water you have placed in the unit is cold, it Petcock will require approximately 35 minutes before vertical or Petcock horizontal 1. LUBRICATE METAL-TO-METAL SEAL. open steam begins escaping from the control valve. or closed Apply lubrication to the point or edge where Since it requires more time to bring cold water up side wall and bevel meet on the inside of to operating temperature than it takes warm or hot...
  • Page 5 9. At the end of the sterilization period, turn the on/off toggle switch to "off" and move the toggle on the control valve to an upright (vertical) position so that the steam is permitted to escape. When the toggle is in an upright position, the steam will escape at maximum.
  • Page 6 MAINTENANCE: 3. CONTROL VALVE, PART NO. 65. (See Fig. 2 & 5. EXCESS PRESSURE RELIEF VALVE, PART NO. 3) To ensure long life and proper operation of 2050CS. (See Fig. 6) This sterilizer is 1. METAL-TO-METAL SEAL. (See Fig. 1) the control valve, periodic cleaning is recom- equipped with a new type of excess pressure mended.
  • Page 7 7. OVERPRESSURE PLUG, PART NO. 1010. This ALL-AMERICAN Sterilizer is equipped How Part No. 2050CS with an additional safety device which is the Works Overpressure Plug, Part No. 1010. The Closed purpose of the overpressure plug is to offer an extra margin of safety whenever the sterilizer is used.
  • Page 8 IMPORTANT STERILIZATION FACTS Steam is an ideal sterilizing agent since It is essential that all sterilizers be PRESSURE GAUGE ACCURACY: The it kills microbes quickly, and steam has regularly checked for proper steam gauges are rated as having an accuracy the additional important property of self- penetration to the center of the load.
  • Page 9 50X AND 75X ELECTRIC MODEL SPECIFICATIONS ADDITIONAL ELECTRIC MODEL Shown with Optional Support Base* Shown with Optional Support Base* Shown with Optional Support Base* odel 50X (25 qt/24 liter) odel 75X (41 qt/39 liter) odel 25X (25 qt/24 liter) Model 50X-120: 120 Volt, 50/60 Hz 1650 watts/13.75 amps Model 75X-120: 120 Volt, 50/60 Hz 1650 watts/13.75 amps Model 25X-120: 120 Volt, 50/60 Hz 1050 watts/8.75 amps Model 50X-240: 240 Volt, 50/60 Hz 1650 watts/6.88 amps...
  • Page 11 ALL-AMERICAN PRESSURE STEAM STERILIZERS PARTS LIST Part No. Description *There is a factory installation fee for the heating element, thermoswitch, and thermometer. We recommend that the heating element, thermoswitch, and thermometer be replaced at Clamp bolt the factory. NO GUARANTEE OR RESPONSIBILITY FOR THE PROPER Pin for clamp bolt FUNCTIONING OF THESE PARTS CAN BE ASSUMED BY THE COMPANY IF Bakelite wing nut...
  • Page 12 ALL-AMERICAN PRESSURE STEAM STERILIZER LIMITED WARRANTY This quality sterilizer is designed and manufactured to provide many years of satisfactory performance under normal use. Wisconsin Aluminum Foundry pledges to the original owner that should there be any defects in material or workmanship during the first year after purchase, we will repair or replace it at our option.
  • Page 13 INSTRUCCIONES DE OPERACIÓN Modelos 50X & 75X Esterilizadores eléctricos de vapor a presión 50X Verlo con una base de soporte opcional, Parte No. 2180 75X Verlo con una base de soporte opcional, Parte No. 4180 ¡CUIDADO! ¡LEA ESTAS IMPORTANTES NORMAS DE SEGURIDAD! SI FALLA EN SEGUIR LAS SIGUIENTES INSTRUCCIONES presión que no estén obstruidos.
  • Page 14 Instrucciones de operación para el esterilizador eléctrico de presión al vapor Modelo 50X/75X. IMPORTANTE: NO OPERE ESTE ESTERILIZADOR ELECTRICO DE PRESION AL VAPOR HASTA QUE HAYA LEIDO TOTALMENTE ESTAS INTRUSIONES DE OPERACIÓN. Limpiando Tapón de Sobrepresión #1010 Manómetro del vapor Válvula de seguridad de Exceso de presión Cuando ha terminado de usar el esterilizador, del equipo...
  • Page 15 Mango de baquelita superior Válvula de control Manómetro del vapor del equipo # 72S Tapón de Válvula de seguridad de Sobrepresión #1010 Exceso de presión #2050CS Tubo de aire de escape #2155-25(50X)/#2155-41(75X) Recipiente de aluminio #2156(50X)/#4156(75X) Mango de lado #405(75X Only) Parrilla encaja dentro del recipiente de aluminio #111(50X)/#151(75X)
  • Page 16 Operación tapa. Entonces coloque un recipiente Petcock empacado dentro el esterilizador. Asegúrese vertical or Petcock horizontal open que el canal tubo del aire de escape (local- or closed 1. LUBRICAR EL SELLO DE METAL A METAL. izado dentro del recipiente) esté en su Lubrique el punto o borde al lado donde la posición, al lado derecho del recipiente pared y el bisel se juntan dentro del fondo (Ver...
  • Page 17 9. Al final del periodo de esterilización ponga el interruptor de palanca on/off en "OFF"y mueva la palanca en el control de la válvula hacia arriba en posición (vertical) para que el vapor pueda escaparse. Cuando la palanca esta en la posición hacia arriba, el vapor se escapa al máximo.
  • Page 18 Mantenimiento: 3. VALVULA DE CONTROL, PARTE No. 65. (Ver 5. VÁLVULA DE SEGURIDAD DE EXCESO DE Fig. 2 & 3) para asegurar larga vida y operación PRESIÓN, PIEZA NO. 2050CS. (Ver Fig. 6) Este apropiada de la válvula de control, es esterilizador está...
  • Page 19 7. TAPON PARA SOBRE-PRESION, PARTE No. 1010. Este esterilizador TODO AMERICANO ¿Como trabaja la Parte No. ESTA EQUIPADO con un aparato adicional de 2050CS? seguridad el cual es un tapón de sobre-presión, Parte No. 1010. El propósito de este tapón es el Cerrado proveer un extra margen de seguridad cuando el esterilizador este en uso.
  • Page 20 DATOS IMPORTANTES DE ESTERILIZACIÓN El vapor es un agente ideal en la esterilización articulo 5, pagina 3, sobre "remover el aire PRESICION DEL MANÓMETRO DE PRESION: porque mata rápidamente los microbios, y, atrapado de escape.) Los manómetros están clasificados por tener una además, el vapor tiene una propiedad importante precisión de 3%-2%-3%.
  • Page 21 MODELOS ELÉCTRICOS MODELO ELÉCTRICO 50X AND 75X Con una base de soporte opcional Con una base de soporte opcional Con una base de soporte opcional odelo 50X (25 qt/24 litros) odelo 75X (41 qt/39 litros) odelo 25X (25 qt/24 litros) Modelo 50X-120: 120 Volt, 50/60 Hz 1650 watts/13.75 amps Modelo 75X-120: 120 Volt, 50/60 Hz 1650 watts/13.75 amps Modelo 25X-120: 120 Volt, 50/60 Hz 1050 watts/8.75 amps...
  • Page 23 LISTA DE PARTES PARA TODOS ESTERILIZADORES AMERICANOS DE VAPOR A PRESION Parte No. Descripción *La factoría cobra por la instalación del elemento de calentamiento, el termo conmutador, Perno de la abrazadera pasador y el termómetro. Recomendamos que el elemento de calentamiento, el termo conmutador, Pasador para el perno de la abrazadera y el termómetro sean reemplazados en al factoría.
  • Page 24 GARANTIA LIMITADA DEL ESTERILIZADOR DE VAPOR A PRESION ALL-AMERICAN La calidad de este esterilizador fue diseñada y fabricada para proveer muchos años de satisfacción de rendimiento bajo el uso normal. Si durante el primer año después de la compra hay defectos de mano de obra o materiales Wisconsin Aluminum Foundry, al dueño original le reparará...

Table of Contents

Save PDF