Troubleshooting Guide; Self Check - Panasonic TH-50VX100U Service Manual

High definition plasma display
Hide thumbs Also See for TH-50VX100U:
Table of Contents

Advertisement

TH-50VX100U / TH-50VX100E

7 Troubleshooting Guide

7.1.

Self Check

7.1.1.
Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. To get into the Self-check mode, press the Down button
on the customer controls at the bottom of the set, at the
same time pressing the OFF-TIMER button on the remote
control, and the screen will show.
If the IIC ports have been checked and found to be incorrect
Or not located then " - - " will appear in place of " OK "
" 01 " in the line of the " PTCT " means the number of blinks of
the Power LED is 1. (Reference to 7.1.2)
" H09 " in the line of the " PTCT " is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the " PTCT " displays when you get into the Self-
check mode for the first time only after the Power LED
blinks.