6 Troubleshooting Guide

6.1.

Self Check

6.1.1.
Display Indication
1. Self-check is used to automatically check the bus line controlled circuit of the LCD display.
2. To get into the Self-check mode, press the volume down button on the right side of the unit, at the same time pressing the
OFF-TIMER button on the remote control, and the screen will show.
Method A Self-check only (A shipment setup is not carried out).
Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button
on the remote control more than 3 seconds.
Method B Self-check+Shipment setup
Press and hold the
button on the right side of the unit and press the OFF-TIMER button on the remote control.
If the IIC ports have been checked and found to be incorrect
Or not located then " - - " will appear in place of " OK "
" 02 " in the line of the " PTCT " means the number of blinks of the Power LED is 2. (Reference to 6.1.2)
" H09 " in the line of the " PTCT " is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the " PTCT " displays when you get into the Self-check mode for the first time only after the Power LED blinks.
15