ASSEMBLING THE TOOL
This section describes how to re-assemble the tool
after maintenance. The following procedure assumes
that the base/magazine is already installed.
• Insert the piston assembly into the tool and engage
the driving blade thru the opening of gate/foot
assembly guiding channel.
• Insert the valve assembly into the head.
• Inspect the head gasket; replace if necessary. Place
the gasket into the groove on the head flange. Some
oil or grease will help to keep it in place during
assembly.
• Insert the head assembly onto the body, making sure
that the gasket stays in place. Screw in place.
After reassembly, always actuate the tool
repeatedly WITHOUT FASTENERS against
a piece of wood to insure proper operation.