Temperature sensor for use with our k6000 or k6002 kits.

Advertisement

Preparing the sensor
12. Preparing the sensor
Cut two 5cm pieces of the supplied copper wire (fig. 1.1). Using a knife, remove the varnish of both
pieces of wire over some 3mm from the ends and tin the ends (fig. 1.1)
Cut the connections of the KTY11, KTY81-22 sensor or eq. at 3mm (fig. 1.2)
Solder both copper wires to the sensor (fig. 1.3)
8
Fig. 1.1
Fig. 1.3
Fig. 1.2