Download Print this page

Drive.web smarty dw240 Installation & Operation Manual

Universal automation controller
Hide thumbs Also See for smarty dw240:

Advertisement

Quick Links

drive.web
Universal Automation Controller
models
dw240, dw241,
dw244,
dw248, & dw249
Installation & Operation Manual
Contents
Design Statements, Warnings
smarty Models, Standard Features
Carrier Ratings and Features
smarty Software and XIO Options
smarty Installation and Front Panel
Carrier Terminals, Dimensions, and Data
smarty Terminals, Ratings, and IO Functions
Get savvy
®
Get started with savvy engineering & design software
Upgrade savvy and smarty, savvy-SFD Upgrade
savvyPanel
smarty Precision Motion Functions and Connections
smarty Comms Interfaces, Modbus, EIP
Free drive.web Online Training Seminars
Certification Statements
This process control equipment to be supplied by Class2, LPS, limited power supply.
Design Statements
EMC Standard, EN 61326-1: 2006, Electrical Equipment for Measurement, Control and
Laboratory Use.
Emissions Class A, Commercial Equipment.
Immunity Table 2, Industrial Equipment.
LVD Standards, EN 61010-1: 2010, Safety Requirements for Electrical Equipment for
Measurement, Control and Laboratory Use and;
EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits.
smarty is an industrial controller designed for permanent installation by qualified professionals.
If it is used in a manner not specified herein the protection provided may be impaired.
smarty and its packaging contain recyclable materials
This device is designed to comply with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
This Class [A] digital apparatus is designed to comply with Canadian ICES-003. Cet appareil numerique de la
classe [A] est conforme à la norme NMB-003 du Canada.
Warning! It is essential that you read and understand this entire manual and the entire contents of the savvy
software Help menu before proceeding with your installation and configuration. See page 6 for savvy installation
instructions. For more information and to download manuals and software, go to www.driveweb.com or contact
us. See page 12.
Warning! Your use of savvy software and drive.web devices may cause motors and machinery to power up
with high Voltages or start or operate in an unexpected, dangerous or lethal way. It is essential that you are
completely familiar with all of the equipment and the system design before attempting to program or edit a
program or connect to any live device. It is also essential that a risk assessment is conducted to identify hazards.
Risks must be reduced to tolerable levels.

SMARTY, SAVVY, SAVVYPANEL, SPEEDY, BARDAC, and DRIVE.WEB are trade marks of Bardac
HG503894Beta13
smarty
Corporation, registered in the U.S. and other countries.
, USB Plug and Play, Ethernet Networking
Touch Screen Operator Station
®
www.driveweb.com
smarty
drive.web automation
Page
1, 2
2
2, 3
3
4
4, 5, 6
7
8, 9
9, 10
10
10, 11
12
12
12
Page # /12
®
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the smarty dw240 and is the answer not in the manual?

Questions and answers

Summary of Contents for Drive.web smarty dw240

  • Page 1 See page 12. Warning! Your use of savvy software and drive.web devices may cause motors and machinery to power up with high Voltages or start or operate in an unexpected, dangerous or lethal way. It is essential that you are completely familiar with all of the equipment and the system design before attempting to program or edit a program or connect to any live device.
  • Page 2 Warning! You are entirely responsible for the configuration or use of any drive.web product. By configuring or using these products you agree to indemnify and hold harmless Bardac Corporation, its employees, directors, officers, distributors, and resellers against the consequences of your configuration or use of the products.
  • Page 3 Carrier 1 Ratings and Features smarty C1 (dw241 only) drive.web distributed process control. 10BaseT / 100baseTX Ethernet. See page 4. USB peripheral, micro B. Eight bipolar analog inputs: -11VDC to +11VDC, 100kΩ, 1kHz. Eight unipolar analog outputs: ~0.2VDC to 10.5VDC, 10mA.
  • Page 4 Status - Blue LED. Status heartbeat pulses twice a second. Fault - Red LED. Check power supply, connect with savvy, or contact us at drive.web for more information. Ethernet link/activity - Orange LED indicates Ethernet connection and blinks for activity.
  • Page 5 Carrier C3 Terminals drive.web automation and Dimensions 8P8C CANopen Serial Port Realtime Clock Battery, CR2032. (Realtime clock will be maintained for approximately 24hrs with no backup battery.) DI = Digital Input DO = Digital Output AO = Analog Output AI = Analog Input...
  • Page 6 Terminals Carrier C4 drive.web automation and Dimensions 8P8C CANopen Serial Port Realtime Clock Battery, CR2032. (Realtime clock will be maintained for approximately 24hrs with no backup battery.) DI = Digital Input DO = Digital Output AO = Analog Output AI = Analog Input...
  • Page 7 Terminals and Ratings smarty Terminal wiring - Strip 7mm(0.28”) or use ferrules. Use 0.2mm (AWG24) minimum. One wire, 2.5mm (AWG12) maximum. Two wires, 1.5mm (AWG14) maximum. Two wires with ferrules, 1mm (AWG18) maximum. Use shielded cable for runs over 30 meters.
  • Page 8 The as-shipped address is 10.189.26.43. Use Category 5e cable or better, with 8P8C/RJ-45 connectors for each drive.web device and the host computer. For systems with more than one drive.web device, use an Ethernet switch for all drive.web devices and computer. Get started with...
  • Page 9 Add function blocks in the order to be processed. Processing order is left to right, top to bottom. Click function blocks to view parameters and details. Connect between parameters and other drive.web devices. Warning! Making a connection results in immediate execution of that connection. Dangerous Voltages and rotating machinery may result! Under the File menu, choose New Viewer...
  • Page 10 A limited set is available without the option. free from the Apple App Store℠ savvyPanel...
  • Page 11 Pages savvyPanel Systems Page where multiple savvyPanel systems are present. A savvyPanel system may contain tiles from many drive.web devices. A drive.web device contributes to only one savvyPanel system. Touch the systems button, , in the window bar to access the systems page from home page.
  • Page 12 Supports up to five simultaneous clients/masters. dwOption-25 EIP/PCCC Server Supports PLC5 Typed-Write and Typed-Read commands. See Appendix B of the savvy User Manual for information and drive.web parameter IDs mapping to PLC5. Supports up to two simultaneous clients. ModbusRTU Type (not available in C1) M=Master-Client, S=Slave-Server, X=None-e.g.

This manual is also suitable for:

Smarty dw241Smarty dw244Smarty dw248Smarty dw249