Frequency Adjustment - Icom IC-4061T Service Manual

Table of Contents

Advertisement

6-2 FREQUENCY ADJUSTMENT

Select an adjustment item using [↑] / [↓] keys, then set to the specifi ed value using [←] / [→] keys on the connected PC's keyboard.
ADJUSTMENT
ADJUSTMENT CONDITION
PLL LOCK
1 • Channel
VOLTAGE
• Lock voltage preset
[RX LVA1]
• Receiving
[RX LVA2]
2 • Channel
• Lock voltage preset
• Receiving
[TX LVA]
3 • Channel
• Lock voltage preset
• Transmitting
PLL LOCK
1 • Channel
VOLTAGE
• Receiving
2 • Channel
• Receiving
3 • Channel
• Transmitting
REFERENCE
• Channel
FREQUENCY
• Connect an RF power meter to the
[REF]
antenna connector.
• Transmitting
• I/O Check window
: 1
[LV (RX1)]
: 51 [1.0 V]
: 2
: 51 [1.0 V]
[LV (RX2)]
: 1
[LV (TX)]
: 51 [1.0 V]
: 4
: 3
: 3
: 3
MEASUREMENT
UNIT
OPERATION
PC
Click [I/O Check] in the Clone
screen
menu to open the "I/O Check
window."
Click [Update (F5)] button, then
check the "LVIN" item on the
CS-F3060 ADJ's screen as below.
PC
Click [Update (F5)] button, then
screen
check the "LVIN" item on the
CS-F3060 ADJ's screen.
Top
Loosely couple a frequency
panel
counter to the antenna connec-
tor.
6 - 4
VALUE
1.00 V
3.4–4.4 V
(Verify)
3.2–4.4 V
(Verify)
470.000000/
512.000000 MHz

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents