JRC JUE-95LT Instruction Manual page 32

Inmarsat mini-c mobile earth station
Hide thumbs Also See for JUE-95LT:
Table of Contents

Advertisement

(An opening number of the button name corresponds to Figure 2-2-2a.)
NAME
(2) POWER lamp
(3) SYNC lamp
(4) LOG-IN lamp
(5) TRANSMIT lamp
(6) RECEIVE lamp
(7) ALARM lamp
*1) TX Alarm informs some sort of malfunction is occurred on communication devices.
*2) Battery Alarm informs the battery is decreased to under the specified level.
The position data reporting might not be able to be transmitted normally when the battery alarm has been
generated, then contact JRC.
Name
(1) POWER switch
(8) RESET button
(9) DIMMER button
Name
EME connector
Power Supply connector
DTE connector
Option Connector
Table 3-1 The status of MES which LED lamps indicated
MES power on
Bulletin Board OK
When the MES is returned the NCS channel
to the TDM channel or the TDM channel to
the NCS channel, this LED blinks.
Logged in
MES carrier on
Message receiving
・When TX Alarm *
intervals of 0.5 seconds.
・When Battery Alarm*
with 1 second interval.
・When both of TX and Battery Alarms are
generated, it lights without blink.
Table 3-2 Function of switch and buttons
Function
Power ON/OFF the MES.
To reset the status of JUE-95LT when it
operates abnormally.
To adjust the brightness of lamps to four
stages.
(Circulates between
Off-Low-Middle-High)
Table 3-3 Connectors and the Cable
IME⇒EME
IME⇒AC adapter of EXT PSU (24V)
IME⇒DTE and DS/DTE
IME⇒JB1 and JB2
ON
1
is generated, it blinks at
2
is generated, it blinks
Refer to chapter 4-6 of this manual and
be careful to handle this button.
(It seems to a very little hole.
Press the switch existed in the hole with
narrow object like a wire.)
Connected from/to
3-2
OFF
MES power off
Bulletin Board NG
Logged out
MES carrier off
No message/ or outputting
received message to DTE or
printer
Normal condition
(To extinction the lamp, turn on
and off the power switch.)
Remarks

Advertisement

Table of Contents
loading

Table of Contents