Westellr 520-10SWI3 Digital Network Interface Unit (NIU)
CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.

GENERAL

1.1
Document Purpose
This document describes the Westellr 520-10SWI3 Digital
Network Interface Unit (NIU), shown in Figure 1.
- NOTE -
Hereafter, the 520-10SWI3 Network Interface Unit will be referred to
as the 520-10SWI3".
1.2
Document Status
This Revision B practice updates the company contact infor-
mation. Revision A created this document and replaced the
previous 783-300001 document. Whenever this practice is up-
dated, the reason will be stated in this paragraph.
1.3
Product Purpose
The 520-10SWI3 is the ultimate solution in terminating a DS1
High Capacity Digital Service (HCDS) at the customer prem-
ises. The 520-10SWI3 is a multifunctional unit that can be
configured as an Office Repeater, a Line Repeater, or as an
NIU. The 520-10SWI3 is typically located on the network side
of the demarcation point between the Network (NET) and the
Customer Premises Equipment (CPE). One of the primary
functions of the 520-10SWI3, in any configuration, is signal
loopback. Loopback enhances maintenance operations by al-
lowing the network to remotely sectionalize problems,
resulting in improved customer service. The universal func-
tionality of the 520-10SWI3 results in simpler and faster
installations of DS1 services as well as providing general sav-
ings in inventory.
1.4
Product Mounting
The 520-10SWI3 is a 200 MECHANICSr module that mounts
in a 200- or 400-mechanics-type mounting (or equivalent
ECopyright 2008 Westell, Inc. All rights reserved.
*CLEI is a trademark of Telcordia Technologies. Westellr and 200 MECHANICSr are registered trademarks of Westell, Inc.
CLEI* Code: T1L4HKFDAA
PAGE #
1
2
. . . . . . . . .
5
. . . . . . . . . . . . . . . . . . . . . . .
5
12
. . . . . . . .
16
17
. . . . . . . . . . . . .
18
. . . . . . . .
18
. . . . . . . . . . . . . . . . . . . . . .
19
19
Figure 1.
Isometric View of 520-10SWI3 NIU
mounting that matches the module's pin-out plan). It is typical-
ly mounted in a DTWA series mounting or other 200
MECHANICSr shelf.
1.5
Product Features
The 520-10SWI3 offers the following features.
S
200 MECHANICSr (front panel is half the width of a
standard 400-type mechanics unit)
S
Powered from 60 mA span current or locally from a

Vdc,
24 Vdc or 24 Vac external source
S
Inband and manual loopback activation and deactiva-
tion
S
Compatible with AMI and B8ZS line formats
S
Lightning and power cross protection at the network
ports
S
Pin-type test jacks for measuring span current
S
Bantam jacks for Monitor/Cut-Thru access
S
Front panel LEDs for:
S
PWR (Power)
S
LPBK (Loopback)
S
Fuse Alarm
S
NET LOS (Network Loss of Service)
Section 520-10S-WI3-203
Equipment Issue 3
030-101591 Rev. B, June 2008

0806I3RB
Page 1 of 19
48

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 520-10SWI3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Westell 520-10SWI3

  • Page 1: Table Of Contents

    NET LOS (Network Loss of Service) in a 200- or 400-mechanics-type mounting (or equivalent ECopyright 2008 Westell, Inc. All rights reserved. 0806I3RB *CLEI is a trademark of Telcordia Technologies. Westellr and 200 MECHANICSr are registered trademarks of Westell, Inc. Page 1 of 19...
  • Page 2: Applications

    Single or Dual Loopback with Arming Office Repeater Loopback 16-bit binary code Line/Extension Repeater Application As a Repeater, the 520-10SWI3 is able to extend DS1 services Line Repeater Features providing bidirectional regeneration of the DS1 signals. The LOCAL, SPAN or THRU Power Options...
  • Page 3 The 520-10SWI3 has different input power options when operating as an Office Repeater, as a Line or Extension As an NIU, the 520-10SWI3 terminates DS1 services at the Cus- tomer Premises for maintenance and transmission conditioning. Repeater or as an NIU.
  • Page 4 Office Repeater Input Power Local Power Requirements When the 520-10SWI3 is powered from an external local power As an Office Repeater, the 520-10SWI3 is powered from an ex- source, the unit is capable of operating from voltage and cur- ternal 48Vdc power supply.
  • Page 5: Circuit/Functional Description

    520-10SWI3 automatically re-routes the simplex cur- rent back to the Network. When the unit is in an open span The 520-10SWI3 is capable of operating as an Office Repeater, condition, an additional 120 Ohms is added to develop the nec- a Line or Extension Repeater, or as an NIU and is configured essary voltage for self-healing functionality.
  • Page 6 Section 520-10S-WI3-203 030-101591 Rev. B Figure 8. 520-10SWI3 Block Diagram 0806I3RB...
  • Page 7 The LPBK TO LED illuminates. To disable the 120-minute automatic loopback timeout feature, do LPBK not press the MLB button. The LPBK TO LED is OFF. The 520-10SWI3 is now configured for service as an office repeater. CLOS CLOS RPTR...
  • Page 8 CPE and regenerates the DS1 signal towards the 60mA with a maximum of 35Vdc. This voltage equates to a re- Network at a 0dB level. sistance design limit of 583 Ohms. The 520-10SWI3 can span power an NIU (250-ohms resistance) at the distances as shown 4.1.6 Loopback Timeout Option in Table 3.
  • Page 9 To disable the 120-minute automatic loopback timeout feature, do LPBK LPBK not press the MLB button. The LPBK TO LED is OFF. The 520-10SWI3 is now configured for service as a Line/Exten- sion Repeater. LPBK TO LED lit steady = LPBK TO LED OFF =...
  • Page 10 Section 520-10S-WI3-203 030-101591 Rev. B front-panel LINE −I and +I pin jacks. The DROP −I and +I While the ESF Only LED is flashing, simply press pin jacks are disabled and provide no span current measurement Only MLB button once to configure unit to detect ESF sig- readings.
  • Page 11 To disable the 120-minute automatic loopback timeout feature, do not press the front-panel MLB button. The LPBK TO LED is OFF. LPBK TO LED lit steady = The 520-10SWI3 is now configured for service as an NIU. LPBK Timeout Enabled LPBK TO LED OFF = LPBK Timeout Disabled Figure 11.
  • Page 12: Loopback

    Loopback remains in effect until the MLB button is pressed a LOOPBACK second time or the loopback deactivate code is received. The primary function of the 520-10SWI3 is loopback. The 5.1.1 Manual Dual Loopback 520-10SWI3 supports both manual and remote loopback func-...
  • Page 13 Section 520-10S-WI3-203 030-101591 Rev. B 4-second timer time out. The LPBK T.O. LED remains After receiving the 16-bit inband code for the specified time off and the unit returns to normal operation. frame, the front-panel LPBK LED illuminates and the 120-minute Loopback Timeout feature (if enabled) is acti- vated.
  • Page 14 Section 520-10S-WI3-203 030-101591 Rev. B 520-10SWI3 Fiber Multiplexer (as Line Rptr) DSX-1 (SPAN) (DSX) (SPAN) Figure 14. Single Loopback Operation Diagram − Line Repeater Mode 520-10SWI3 Fiber Multiplexer (as Line Rptr) DSX-1 (DSX) (SPAN) (SPAN) Figure 15. Dual Loopback Operation Diagram − Line Repeater Mode Remote Loopback (Line Repeater Mode) 5.3.2...
  • Page 15 Section 520-10S-WI3-203 030-101591 Rev. B vated. After 120-minute time frame, loopback After receiving the code for the specified time frame, the front- automatically releases and the unit returns to normal opera- panel LPBK LED illuminates and the 120-minute Loopback tion. Timeout feature (if enabled) is activated.
  • Page 16: Options & Front Panel Features

    LOOPBACK XMT TO (NOT USED) Figure 16. Front Panel and Option Location Diagram of the 520-10SWI3 this condition because of a loss of signal from the customer, an Front Panel Features override of this condition can be accomplished by sending the loop-down code 11100 for five seconds minimum or four consec- 6.1.1...
  • Page 17: Installation

    PCB Option Switches (Side Panel) CAUTION - STATIC-SENSITIVE This product contains static-sensitive components! Proper The 520-10SWI3 contains six option switches on the PCB to op- electrostatic discharge procedures must be followed to tion the unit for proper operation. The locations of these maintain personal and equipment safety.
  • Page 18: Testing & Troubleshooting

    CUSTOMER & TECHNICAL SERVICES TESTING & TROUBLESHOOTING If technical or customer assistance is required, contact Westell by calling or using one of the following options: Testing Testing consists of performing the steps outlined in Table 8.
  • Page 19: Warranty & Repairs

    10.1 Warranty D. Loop-up Code: Westell warrants this product to be free of defects at the time Inband (unframed or SF): 11000 (>5 sec.) of shipment. Westell also warrants this product to be fully func- ESF DL − 0001 0010 1111 1111 (>16ms);...

Table of Contents