Electrical & Grounding Requirements - Kenmore 795.7303 Series Use & Care Manual

Hide thumbs Also See for 795.7303 Series:
Table of Contents

Advertisement

Available languages

Available languages

Your old refrigerator may have a cooling system
that used CFCs or HCFCs (chlorofl uorocarbons or
hydrochlorofl uorocarbons). CFCs and HCFCs are
believed to harm stratospheric ozone if released to the
atmosphere. Other refrigerants may also cause harm to
the environment if released to the atmosphere.
IMPORTANT: Please read carefully.
TO CONNECT ELECTRICITY
WARNING
Electrical Shock Hazard
FOR PERSONAL SAFETY, this appliance must be
properly grounded. Have the wall outlet and the circuit
checked by a qualifi ed electrician to make sure the
outlet is properly grounded.
3-prong
grounding type
wall receptacle
3-prong
grounding
plug
RECOMMENDED GROUNDING METHOD
The refrigerator should always be plugged into its own
individual properly grounded electrical outlet rated for
115 Volts, 60 Hz, AC only, and fused at 15 or 20 amperes.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a fi re
hazard from overheated wires. It is recommended that a
separate circuit serving only this appliance be provided.
Use a receptacle that cannot be turned off with a switch
or pull chain. Do not use an extension cord.
Where a standard two-prong wall outlet is encountered,
it is your personal responsibility and obligation to have
it replaced with a properly grounded three-prong wall
outlet.
CFC/HCFC DISPOSAL
ELECTRICAL & GROUNDING REQUIREMENTS
Ensure proper
ground exists
before use.
If you are throwing away your old refrigerator, make
sure the refrigerant is removed for proper disposal
by a qualifi ed technician. If you intentionally release
refrigerant, you may be subject to fi nes and imprisonment
under provisions of environmental legislation.
USE OF EXTENSION CORDS
WARNING: Do not use extension cords or ungrounded
(two-prong) adaptors. Because of potential safety
hazards under certain conditions, the use of an extension
cord is not recommended. However, if you still elect to
use an extension cord, it is absolutely necessary that it
be a UL-listed (USA), 3-wire grounding type appliance
extension cord having a grounding type plug and outlet,
and that the electrical rating of the cord be 15 amperes
(minimum) and 120 volts.
Use of an extension cord will increase the clearance
needed for the back of the refrigerator.
Replacing Electrical Cord
To avoid hazard, damaged power cords must be
replaced by the manufacturer or its service agent or
a similarly qualifi ed technician. Do not operate the
appliance with a damaged power cord.
7
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents