LED Light Behavior
The Pendant contains two LED lights, one red and one green. These serves various
functions depending on the Pendant configuration and state. During normal operation the
red and green LEDs communicate battery status and provide visual indication that the
Pendant is operational. During an alarm condition the red and green LEDs indicate the
status of the alarm and the communication of this alarm to the Server software. The LED
behavior is outlined in the table below.
Pendant
Condition
Normal
Battery installed and
Operation
Pendant operating
properly
Check
User presses button <1
Working Status
second. If the button is
pressed and released 5
times in quick
succession, the Pendant
sends a check-in packet
to the Server,
In Alarm
User presses button >1
second
Alarm
Security acknowledges
Acknowledged
Alarm event on the
Help Alert software.
Software sent
acknowledged packet to
alarmed Pendant.
Staff Duress Pendant (0510-0332-A) - User Guide
Condition
Green— indicates battery status OK.
Red—indicates battery needs
replacement.
Red—illuminates once for each
button press to indicate button
operational.
Green—illuminates once if
successfully communicating with the
Server software,
Red—illuminates for 10 seconds to
indicate that the Pendant is scanning
for nearby Reference tags.
Green—illuminates for 10 seconds
to indicate that the Pendant is
scanning for nearby Reference tags.
Description
The Staff Duress Pendant
Frequency
Duration
Every 10
100 ms
seconds
(configurable 0
to 255ms)
Every 10
Duration of
seconds
button press < 1
second
Every 10
10 seconds
seconds
Every 10
10 seconds
seconds
5
Need help?
Do you have a question about the Help Alert and is the answer not in the manual?
Questions and answers