since the information is backed up and stored in the
device.
Procedures to obtain and register the license key
(1) Access to the LMS clicking the URL below, and
obtain a license key following instructions displayed
on the screen step by step.
The URL of the LMS
http://www.canon.com/lms/ir/
When users obtain a license key, both the 16-digit
number on the License Access Number Certificate
Sheet and the serial No. (e.g.: ABC01234) of the
device to be installed are required. The device serial
No. is displayed in the "Serial Number" when the
counter key of the iR is pressed.
(2) Write down the 16-digit number displayed on the
Web in the space provided on the license access
number certificate sheet.
MEMO:
The 16-digit license key number can be printed out
last with LMS.
Make sure to transcribe correctly. Give an appropriate
explanation to users so that they will keep License
Access Number Certificate Sheet surely.
(3)
Press
the
Additional
settings>License Registration, then input the license
key in the designated space, and press Start key so that
the license key is registered and the function of the
option is validated.
If the function fails to be validated, an error message
will be displayed. Refer to the followings what action
to be required.
function>System
"There are not enough required features for install."
>> Check if the USB Application Interface Board-D1
is recognized correctly and also check if the RAM
capacity is 512MB. The special option may be needed
with the copier product used.
"The value for the license key is incorrect. Check the
license key."
>>Check if the license key issued to another device is
used.
>>Check if the license key is input wrongly.
>>Check if the license key is correct.
"This function has already enabled."
>>Check if the security function has already been
enabled.
(4) Press the power switch on the control panel for 3
seconds or more.
displayed on the shutdown sequence step by step with
operations to select appropriate items on the touch
panel so that the main switch can be ready for turning
off. Turn the main power off, and after 10 seconds,
turn it on again.
(5) The registered license will be validated when the
power supply of the device itself is turned on once
again.
At the first reboot after the license key registration, in
some cases, it might take 30 min. or more in order to
initialize the data in HDD. If the data erasing method
of HDD of the device is set to "Overwrite random data
3 times", it might take longer than the cases above.
Make sure not to turn off the power supply when the
message, "Remaining data that is not needed is being
erased. Do not turn off the main power.", is displayed.
(6) When the device starts normally, press counter key
and then press the Device Configuration to check if
the security kit is displayed in the space of options.
Then, set the Service mode at user's request.
Chapter 1
Following the instructions
9