AOpen A70PF Service Manual page 8

Table of Contents

Advertisement

﹟ Test Meter
ITEM
﹡ Test Point
﹫ Pattern
Program Menu.
﹟ Color Analyzer
Background
White
﹫ R.G.B off
Balance
(68KHz,1024x768)
D
Adjust
﹟ Color Analyzer
White
Balance
﹟ Oscilloscope
Adjust
﹡ Cathode G
E
﹫ 3" block
(68KHz,1024x768)
﹟ Color Analyzer
ABL
Adjust
﹫ Full White
F
(68KHz,1024x768)
﹫ Full White
Other
Function
(85Hz 1024*768)
Seting
G
A70PF(RX-777NS)
Operation
1. Set the contrast to MAX.,Brightness to Y=0.7
° K
set color is 9300
using the OSD.
2. Set the OSD to COLOR of sub menu and press
knob.
3. Make the adjustment R.G.B BIAS low light to
the value shown at right by using
1. Move the OSD to the R.G.B. DRIVE.
2. Move the OSD to the G DRIVE and make the
adjustment to the value shown at right by using
and key.
3. Move the OSD to the R,B-DRIVE and make the
Adjustment to the value shown at right by using
and
key.
1. Set the contrast to MAX.,Brightness to MAX.
2. Make the adjustment to the value shown at right
by adjustment ABL on the OSD menu.
1. Set the FREQ. to 73
2. Set the OSD to PROVIEW
3. Set the BURN to Disable
4. Set the DEFO to TDA9116/9118
Adjusting
Value
Y = 0.4
± 0.1FL
x = 0.283
± 0.015
y = 0.297
and
key.
± 0.015
37V
P-P
Y=58FL
x = 0.283
± 0.015
y = 0.297
± 0.015
33FL ± 3
Y =
8 / 33