ElmoTech MU-800-2 Operational Manual

Electronic monitoring system, mobile unit

Advertisement

Quick Links

ELECTRONIC MONITORING SYSTEM
MOBILE UNIT OPERATIONAL
GUIDE
(MU-800-2)

Advertisement

Table of Contents
loading

Summary of Contents for ElmoTech MU-800-2

  • Page 1 ELECTRONIC MONITORING SYSTEM MOBILE UNIT OPERATIONAL GUIDE (MU-800-2)
  • Page 2 Forward Information in this documentation is subject to change without notice and does not represent a commitment on part of ElmoTech Ltd. The software described in this document is subject to the license agreement that is included with the product, which specifies the permitted and prohibited uses of the product.
  • Page 4: Table Of Contents

    Table of Contents TABLE OF CONTENTS Section Page 1 INTRODUCTION................1-1 1.1 About the Mobile Unit................ 1-1 2 GETTING STARTED ..............2-1 2.1 About This Manual ................2-1 2.2 Document Conventions ..............2-2 3 MOBILE UNIT ACTIVATION AND OPERATIONAL INSTRUCTIONS ................3-1 3.1 Parts of the Mobile Unit..............
  • Page 5 Table of Contents 3.5 Managing the Mobile Unit’s Memory ..........3-7 3.5.1 Managing the Event Log ............... 3-7 3.5.1.1 Viewing the Event Log............3-7 3.5.1.2 Deleting the Event Log............3-8 3.5.2 Managing the Members List............3-8 3.5.2.1 Viewing the Members List ............. 3-8 3.5.2.2 Adding / Editing a Member’s Name........
  • Page 6: Introduction

    Introduction 1 Introduction 1.1 About the Mobile Unit The Mobile Unit (MU ) is based on Elmo-Tech’s field proven RF technology and is one of the many unique elements of the Monitoring System. The Mobile Unit is a lightweight, palm sized, portable monitoring device that can be used by mobile officers in the field to detect the presence of clients wearing Elmo-Tech Transmitters.
  • Page 7: Getting Started

    Electronic Monitoring System. This manual does not contain information regarding system settings, configuration or any other software produced by ElmoTech Ltd., unless directly related to this produce. Please refer to the appropriate manuals for information with respect to the Mobile Unit Monitor Operator’s manual.
  • Page 8: Document Conventions

    Getting Started All Mobile Unit related hardware and software must be installed and repaired by a qualified ElmoTech Ltd. customer service representative or an experienced system administrator. 2.2 Document Conventions A Table of Contents and Table of Figures are included in this manual in order to help you quickly and easily find the information that you need.
  • Page 9: Mobile Unit Activation And Operational Instructions

    Mobile Unit Activation and Operational Instructions 3 Mobile Unit Activation and Operational Instructions 3.1 Parts of the Mobile Unit Antenna LED Indicators Infrared panel A-Display Panel Button Down Button Charging Socket 3.1.1 A-Display Panel Tx ID number Current time 4 0 1 9 3 - - - - 0 3 : 4 6 Tx tamper status...
  • Page 10: Activating The Mobile Unit

    Mobile Unit Activation and Operational Instructions 3.2 Activating the Mobile Unit To activate the Mobile Unit while in Off mode: Connect one end of the power adapter into the wall socket and connect the other end into the charging socket on the Mobile Unit. To activate the Mobile Unit while in Standby mode: Press the Down button continuously for about 3 seconds.
  • Page 11 Mobile Unit Activation and Operational Instructions The Menu bar is located in the upper section of the Display panel and can be used to navigate through the appropriate menu options. The Control bar is located in the lower section of the Display panel and, by using the Up and Down buttons on the Mobile Unit, can be used to...
  • Page 12: Defining Mobile Unit Operational Settings

    Mobile Unit Activation and Operational Instructions 3.4 Defining Mobile Unit Operational Settings To enter the Settings menu: Navigate to the Main menu and select Settings. The Settings menu is displayed. < S E T > [ O P R ] S Y S T I M O p e r a t i o n a l O p t i o n s...
  • Page 13: Changing The Keypad Tone

    Mobile Unit Activation and Operational Instructions 3. Select Set to save the new setting. 3.4.3 Changing the Keypad Tone To change the keypad tone: 1. With the Setting menu displayed, select Operational Settings and choose Keypad Tone settings. 2. Select Next until the desired setting is displayed. The Keypad Tone setting options are;...
  • Page 14: Changing The Date And Time

    Mobile Unit Activation and Operational Instructions 3.4.6 Changing the Date and Time To change the date and time: 1. With the Setting menu displayed, select Date and Time settings. The currently set date and time is displayed. 2. Select Edit to enter Date and Time settings. 3.
  • Page 15: Managing The Mobile Unit's Memory

    Mobile Unit Activation and Operational Instructions 3.5 Managing the Mobile Unit’s Memory Before you start a new monitoring session, you have the option to view and / or delete all redundant data previously stored in the Mobile Unit’s memory. To enter to the Memory Management menu: Navigate to the Main menu and select Memory Management.
  • Page 16: Deleting The Event Log

    Mobile Unit Activation and Operational Instructions 3.5.1.2 Deleting the Event Log To delete the event log: 1. With the Event Log menu displayed, select Next until the Delete Event Log option is displayed and then select Enter. 2. Select Yes to confirm the deletion, or select No to return to the Memory Management menu.
  • Page 17: Deleting The Members List

    Mobile Unit Activation and Operational Instructions 4. Select Toggle until the desired letter is displayed and then select Next to move onto the next letter. 5. Repeat this process until the members name has been entered into the Name field. 6.
  • Page 18: Monitoring Offenders

    Mobile Unit Activation and Operational Instructions 3.6 Monitoring Offenders You can use the Mobile Unit to monitor the continuously changing status of all Transmitters currently present within the defined range of the Mobile Unit, or you can lock onto and search for a single Transmitter. 3.6.1 Monitoring All Transmitters Once the Mobile Unit has been activated the unit automatically enters into monitoring mode.
  • Page 19: Status Indicators

    Mobile Unit Activation and Operational Instructions 2. Once the desired Transmitter ID is displayed, select Lock. The Mobile Unit locks onto the selected Transmitter and a visual tracking gauge is added to the Display panel 4 0 1 9 3 - - - - 0 3 : 4 6 S t a t u s : B D S T _ _ _ _...
  • Page 20 Mobile Unit Activation and Operational Instructions 3.7 Activating the Remote PC Connection Once you have completed a monitoring session, you have the capability to upload any stored data from the Mobile Unit directly to the Mobile Monitoring System software application on the desktop computer. Note that, you must have the Mobile Monitoring System software application and an Infrared Reader installed on your desktop computer before you activate the remote PC connection.
  • Page 21: Charging The Mobile Unit

    Do not attempt to fix the unit by yourself. For agencies / customers: Do not use faulty units at any time. If any of the above malfunctions occur, return the unit to ElmoTech for repair. 3-13 Mobile Unit Operational Guide...
  • Page 22: Maintaining & Packing The Mobile Unit

    Maintaining & Packing the Mobile Unit 4 Maintaining & Packing the Mobile Unit 4.1 Cleaning the Mobile Unit To clean the Mobile unit: 1. Remove the Mobile Unit from its water resistant carrying pouch and simply wipe the outside of the unit with a damp cloth. Do not, under any circumstances, submerge or place the Mobile unit under running water.
  • Page 23: Mobile Unit Specifications

    Mobile Unit Specifications 5 Mobile Unit Specifications Mobile Unit Features • • Light, palm sized and water- Minimizing direct resistant new design unnecessary contact with offenders • Ability to verify monitored • offender compliance while Extended memory capacity patrolling in a vehicle, or on •...
  • Page 24 Mobile Unit Specifications FCC Information FCC ID: LSQ-MU-800-2 FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information. This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause...

Table of Contents