Important Service Notes (111H For Uk Only); Specifications - Sharp QT-CD111H Service Manual

Hide thumbs Also See for QT-CD111H:
Table of Contents

Advertisement

FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER
TO THE OPERATION MANUAL.

IMPORTANT SERVICE NOTES (111H FOR UK ONLY)

Before returning the unit to the customer after completion of a repair or adjustment it is necessary for the following withstand voltage
test to be applied to ensure the unit is safe for the customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Withstanding Voltage Tester
Test voltage
Set time
Set current (Cutoff current)
Unit
Judgment
OK: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzor sounds.
General
Power source:
Power consumption:
Output power:
(111H Except for UK/
110H)
Output power:
(111H For UK)
Speakers:
Output terminal:
Dimensions:
Weight:
Radio
Frequency range:
Set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA

SPECIFICATIONS

AC 230 - 240V, 50 Hz
DC 12 V [ "D" size (UM/SUM-1,
R20 or HP-2) battery x 8]
11 W
PMPO; 28 W
MPO; 8.4 W (4.2 W + 4.2 W)
(AC operation, DIN 45 324)
RMS; 4.6 W (2.3 W + 2.3 W)
(DC operation, DIN 45 324)
MPO (Max.); 8.4 W (4.2 W + 4.2 W)
(AC operation)
RMS; 4.6 W (2.3 W + 2.3 W)
(DC operation, 10 % T.H.D.)
10 cm (4") full-range speaker x 2
Headphones; 16-50 ohms
(recommended; 32 ohms)
Width; 480 mm (18-15/16")
Height; 153 mm (6-1/16")
Depth; 254 mm (10")
3.2 kg (7.1 Ibs.) without batteries
FM; 87.5 - 108 MHz
AM; 526.5 - 1,606.5 kHz
WITHSTANDING
VOLTAGE TESTER
AC
OUT
SHORT-CIRCUT
AC POWER
SUPPLY CORD
Tape recorder
Frequency response:
Signal/noise ratio:
Wow and flitter:
(111H Except for UK/110H)
Wow and flitter:
(111H For UK)
Motor:
Bias system:
Erase system:
Compact disc player
Disc:
Signal readout:
Audio channels:
Quantization:
Filter:
D/A converter:
Wow and flutter:
Specifications for this model are subject to change without
prior notice.
– 3 –
QT-CD111H/110H
PROBE
UNIT
CONNECT THE PROBE
TO GND OF BATTERY
SPRING
50 - 14,000 Hz (Normal tape)
50 dB
0.3 % (DIN 45 511)
0.25 % (WRMS)
DC 12 V electric governor
AC bias
Magnet erase
Compact disc
Non-contact, 3-beam semi-
conductor laser pickup
2
16-bit linear quantization
4-tims oversampling digital filter
1-bit D/A converter
Unmeasurable
(less than 0.001% W. peak)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QT-CD111H and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Qt-cd110h

Table of Contents