Electrical Specifications - Dekolink MW-CBDA-SMR-800-900-1W65 Installation And Operating Instructions Manual

Dual band compact bi-directional amplifiers
Table of Contents

Advertisement

Electrical Specifications

Downlink Frequency Range
Uplink Frequency Range
Passband Gain @ min attenuation
Passband Ripple
Output Power AGC Set
AGC Selection
AGC Dynamic Range
AGC LED Indication
MGC (Manual Gain Control) Dynamic Range
Noise Figure @+25°C and max gain
3rd Order Intercept point
IMD @2 tone @+20 dBm/Carrier
VSWR
Downlink alarm turn on
Power Supply
Dekolink Wireless Ltd.;16 Bazel St.Qiryat-Arieh Petah-Tikva Israel, 49510
Tel- 972-3-9180-180; Fax-972-3-
Web site-
www.dekolink.com
851 – 869 MHz
935 – 941 MHz
806 – 824 MHz
896 – 902 MHz
65 dB nominal
±1.5 dB typical
+24± 1 dBm
By ON/OFF Switch
25 dB typical
LED turn ON when power reaches AGC Set
Power Level. (both at On and Off positions).
15 dB min
6.0 dB max
+44 dBm typical
48 dBc typical
1.5 : 1 max
DL power <15 dBm
80 to 240 VAC; 50 to 60 Hz; @500 mA
9180
-
190
; Email-marketing@dekolink.com;
r
ev 0 11/
04
page 13 of 16