Summary of Contents for Adam Pumps DI-FLOW IN-LINE Diesel
Page 1
cabinets, meter, DC and AC pumps, accessories, repair kit USE AND MAINTENANCE MANUAL DIGITAL FLOW METER IN-LINE IN-LINE 12V pulses version...
Page 2
4.4 DIAGNOSTIC 5. TECHNICAL DATA 6. EXPLODED VIEW AND SPARE PARTS LIST 0.��� ������������ ��������� ��� ������������ ��������� ADAM PUMPS SPA Via della Resistenza, 46/48 41011 Campogalliano (Modena) - Italy states, taking full responsibility, that the following meter models digital flow meter“DI-FLOW IN LINE” version “diesel”,“AddBlue®” comply with the Directive for Safety of Machinery: 2006/42/����...
Page 3
• Any type of service, maintenance, control must be done by qualified personal. • During maintenance operations and services, make sure to have disconnected the power supply. • Do not exceed the maximum pressure of 3,5 bar DI - FLOW IN LINE• ADAM PUMPS...
Page 4
• Water �D����F�������� D��� Name and address of the manufacturer:: THE METER IS ��� ��������B�� with other ADAM PUMPS SpA liquids and particularly not compatible with ga- Via della Resistenza 46/48 soline, gas, alcohol and hydrochloric acid. 41011 Campogalliano (Modena) - Italy If in doubt about the compatibility of a specific �achine identification: Contalitri flussimetro...
Page 5
The meter alter is threaded 1” BSP-P female both at inlet and simbol outlet. Sealing is made using O - ring 30x3 70Sh. DI - FLOW IN LINE• ADAM PUMPS...
Page 6
3.3.1 ���B��� 3.4.1 “��R����” ���R��� continued pressure simple pressure 3.4 ���� FU�������� The meter switches on automatically when a transaction starts or when a button is pressed. Displays 4.2 digits, switches on while pressing a The display switches off automatically when no button or detecting pulses at transaction start.
Page 7
Should you maintain the button pressed, the value will change rapidly. To confirm, wait 10 seconds until the “partial” screen I displayed. DI - FLOW IN LINE• ADAM PUMPS...
Page 8
3.5 ������D�RY FU�������� The device has some secondary function, neces- sary to the good operation of the meter which are: calibration, unit selection and instantaneous flow rate. 3.5.1 �����BR����� The meter is supplied with a pre-calibration car- ried out for liquid diesel at 20 °C. Calibration is required when metering a different fluid, after dis- assembly, at different temperature or after signifi- cant wear.
Page 9
“Unit” will be displayed Starting from “Partial” screen: (see table page 9) 3. press to confirm 4. press to scroll between unit: “litres”- “us-gal” –“quarts” – “pints” – “custom” 5. press to confirm. DI - FLOW IN LINE• ADAM PUMPS...
Page 10
TASTO/ COMBINAzIONE TASTI FUNzIONE reset partial screen (only if transaction is not going on visualize the instantaneous flow rate (only when transaction is ongoing) visualize first transaction in history visualize second transaction in history visualize third transaction in history visualize fourth transaction in history visualize fifth transaction in history visualize first transaction in history visualize total of first two transactions in history...
Page 11
2. Exchange the 2 batteries with 2 AAA 1.5V alkali- ne batteries 3. Reposition the body on the cover taking care of not squeezing wires. 4. Screw the 4 screws to tighten the body to the cover. DI - FLOW IN LINE• ADAM PUMPS...
Page 12
4.3 �����K If the meter has to be positioned in stock for a while, clean it carefully. This will help to prevent eventual damages. 4.4 D��G������� �R�B��� �����B�� ���U�� ���U����� The meter is not 1. turbine is blocked 1. Disassemble & reading 2.
Page 13
6 . �x���D�D V��W & ���R� ��R�� DI - FLOW IN LINE• ADAM PUMPS...