Page 1
Device status indicator applications. 1 green blink every 2 seconds Node is sampling Use this document to deploy the SG-Link-200 for data collection. This includes Blue LED during sampling Node is resynchronizing electrical wiring, mounting the device, and using SensorConnect software to...
Page 2
0 to 2.5 V White, Sensor Ground Channel 1 Sensor Input - Analog Input 0 to 2.5 V blue stripe Table 3. SG-Link-200 Quarter-Bridge Pinout Descriptions White, Sensor Ground green stripe Table 2. SG-Link-200 Full and Half-Bridge Pinout Descriptions with Optional Cable Colors...
Page 3
SG-Link -200 ® Quick Start Guide Figures 2 through 5 illustrate Full-Bridge (Standard), Half-Bridge, Two Wire Quarter-Bridge, and Three Wire Quarter-Bridge wiring. Figure 4. Two Wire Quarter-Bridge* Figure 2. Full-Bridge (Standard) Figure 5. Three Wire Quarter-Bridge* * Requires optional on-board bridge completion Figure 3.
Page 4
Mounting Recommendations Node Operational Modes The SG-Link-200 may be mounted using the holes sized for M8 fasteners. Sensor nodes have three operational modes: active, sleep, and idle. When Stainless steel compression limiters are rated for up to class 10.9 bolts sampling, the node is in active mode.
Page 5
Install the SensorConnect software on the host computer before connecting Several methods can be used in SensorConnect to establish communication hardware. Access the free software download on the LORD Sensing website. with the nodes: the automatic node discovery on the same frequency, automatic node discovery on a different frequency, and add node manually.
Page 6
SG-Link -200 ® Quick Start Guide Highlight the new node being added and select Move Node to Frequency (#). If the node was successfully added, two confirmation messages appear and it will be listed under the Base Station. Figure 13. Add Node Confirmation Figure 11.
Page 7
SG-Link -200 ® Quick Start Guide Configure Node The Hardware menu tab displays the current node settings. Node settings are stored to non-volatile memory and are configured using 1. To change the default Input range settings, use the dropdown menus SensorConnect.
Page 8
SG-Link -200 ® Quick Start Guide Configure Sampling Setting and Start Data Acquisition 3. Select Apply and Start Network. A message indicates the Network Started and includes a shortcut link to the Data Tab. 1. Click the Base Station > Sample Network tile, and indicate the nodes to be sampled by checking the box to the left of each node in the list.
Page 9
Radio Specifications The Time Series Graph displays with “No channels selected”. View the The SG-Link-200 employs a 2.4GHz IEEE 802.15.4 compliant radio transceiver available channels and options under the Node’s V Menu. for wireless communication. The radio is a direct-sequence spread spectrum radio and can be configured to operate on 16 separate frequencies ranging from 2.405 GHz to 2.480 GHz.
Power Supply Apply only the input voltage range specified for the SG-Link-200. Connect to a power source that is near the device, is accessible, and adheres to all national wiring standards. Compliance with wiring standards is assumed in the installation of the power source and includes protection against excessive currents, short circuits, and ground faults.