  • Page 1 VENTFREE / FLUELESS GAS FIRE INSTALLATION & OPERATING INSTRUCTIONS Please read these instructions carefully before installation - use and retain them for future reference VFDI 800 These appliances conform to the requirements of SANS 1539. LPGSA Permit Number: Model VFDI800: Permit No:1013-30/1-RSA-12-A...
  • Page 2 CONGRATULATIONS Thank you for purchasing your new CHAD-O-CHEF Gas Fireplace manufac- tured to high standards and tested for compliance with SANS 10087-1 The manufacturer and /or its agents and distributors will not be held re- sponsible for injuries or damages caused by faulty or incorrect installation or use of the appliance.
  • Page 3: Specifications

    SPECIFICATIONS Model VFDI800 Gas type Operating pressure 2.8 kPa Min Regulator size to comply with SANS 1237 2 kg / hr Max. gas consumption 0.64 kg / hr Max. mJ input 36 mJ / h Max. kW input 9 kW / h CO/CO2 Ratio 0.005 Gas inlet connection...
  • Page 4 INSTALLATION INSTRUCTIONS FOR QUALIFIED GAS INSTALLER Unpacking Carefully undo strapping to separate loose parts and remove all plastic protec- tive sheeting. Positioning and Sizing Confirm that the size of Fireplace chosen is the right size for the room. Build up a masonry platform to the customers design, with a suitable hole to drop the fireplace into, so that it rests on the surrounding rim.
  • Page 5: Pressure Testing

    DUNGS BM733 VALVE OPERATING INSTRUCTIONS The ODS pilot is situated on the side of the burner. The gas control valve is accessible by removing the lower door. Grip a knob in each hand and pull forward, to break the magnetic hold. 1.
  • Page 6: Lighting Procedure

    MERTIK VALVE OPERATING INSTRUCTIONS LIGHTING PROCEDURE. 1. Turn ON/OFF Knob A slightly left towards the IGNITION position stop, press down and hold for 5 seconds (gas flows only to the pilot burner). 2. Continue pressing down Knob A while turning further left to activate the spark; hold down for 10 seconds after pilot burner has been lit.
  • Page 7 NG6801 VALVE OPERATING INSTRUCTIONS The ODS pilot is situated on the side of the burner. The gas control valve is accessible by removing the lower door. Grip a knob in each hand and pull forward, to break the magnetic hold. 1.
  • Page 8  inside the burner & the white decorative stone (if applicable) surrounding the burner. Ensure that the coals or pebbles supplied by Chad-O-Chef are placed as rec-  ommended with a 10mm gap between them. DO NOT use more coals or pebbles than recommended and supplied.
  • Page 9: Carbon Monoxide Poisoning

    WARNING This appliance shall not be installed in separately enclosed bathrooms. WARNING This is an un-vented gas fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate ventilation must be provided. Refer to the appropriate section of the user manual. WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH...
  • Page 10 CLEANING Should soot deposits appear on the stainless mosaic tiles, first clean with a dry cloth when cold, and follow up with a cloth dampened with methylated spirits and a final buffing with a dry cloth. Do not use an oil based cleaner, as the oil tends to dis- colour the tiles when heated.