AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems TABLE OF CONTENTS SECTION 1 SECTION 5 General Information Maintenance & Service 1A. Description ............1 5A. Preventative Maintenance Schedule ..... 9 1B. Specifi cations ............1 5B. Air Compressor Servicing ........9 5C. Digital Flow Meter Servicing ........ 9 5D.
Page 3
The Toxicol- ogy Group, LLC, a division of NSF International (Ann Arbor, MI), to provide a professional opinion that the AGW-4015/4025 /4045Mobile Recirculating Ozone Sanitation System poses no safety concerns when operated under the pre scribed con di- tions as set forth in the owner’s manual.
DEL if further explanation is re quired. 2B. Electrical Main Power Supply Circuit: Water Requirements: The AGW-4015/4025/4045 is sup plied with a stan dard Temperature: ... 40°F - 90°F 25 Foot power cord. Plug cord into standard 230VAC (20 Pressure: ....0 - 10 psi Amp) grounded re cep ta cle.
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems SECTION 4 Operation 4A. Control Panel Overview 4A-1. Indicator Lights 4A-2. Other External Components a. Green Lights a. Main Power Switch: Activates water pump and 1) Main Power (Ozone Generator): indicates supplies power to ozone generator.
-5 in.Hg. vacuum. Ensure that the back pres sure gauge is at or above 18 psi for AGW-4015/4025 and at or above 8 psi for the AGW-4045. Ozone On green light will il lu mi nate upon reach- ing approximately -5 in.
4E-1b. General Tank Sanitation - See page 3, drawing 3B. Wash debris and rinse the tank with clean water. Connect the AGW-4015/4025/4045 to the tank and recirculate the system while spraying with any standard spray ball. Approximate spray time is 15-30 minutes.
I. Symptom:“PUMP ON” green indicator light out when MONTHLY: MAIN POWER switch is in the “ON” position. 1. Remove & clean ozone generator cabinet air fi l- 1. No power to the AGW-4015/4025/4045 from the power ter. supply. 2. Perform general cleaning of cabinet exterior.
Solenoid valve may be stuck in closed posi- a. Check back pressure gauge - gauge should read tion. Free plunger and return system to normal approximately 18 psi for AGW-4015/4025 and 8 op er a tion. psi for AGW-4045.
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems 7A-3. Micro-Flocculation and Oxidation SECTION 7 Ozone Overview & Safety Procedures Ozone oxidizes the following metals (know as mi- cro-fl occulation), enabling their removal via fi ltration: 7A. Ozone Use and Technology Overview • Iron 7A-1.
0.01 - 0.10 ..Range of odor threshold 0.1 ....... Permissible concentration (8 hour work day)* is produced by the AGW-4015/4025/4045 (the phys i cal 0.3......Permitted short-term exposure (15 min.)* prop er ties of ozone make this unavoidable). Lab o ra to ry 0.01 - 1.0 ....
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems 7E. Monitoring 7D. Precautions for Safe Handling & Use 7E-1. Location of Monitors 7D-1. Ozone Monitors Ambient ozone detection monitors shall be located Ambient ozone monitoring equipment should be in- to monitor ozone room air and production/plant room stalled in the areas where ozone is being generated air for indoor applications.
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems 7F. First Aid Procedures ® b. The ChromAir System ozone badge (K&M 7F-1. General Environmental P/N 380010-10; www.kandmenvi- First Action: ronmental.com; 1-800-808-2234) may be used 1. DO NOT PANIC. for personnel or area monitoring for ex po sure 2.
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems Page 1 of 3 Material Safety Data Sheet NFPA 704 Designation Hazard Rating This MSDS complies with OSHA’s Hazardous Communication Standard 29 CFR 1910.1200 and OSHA form 174. 4 = Extreme DEL Ozone 3 = High...
Page 23
AGW-4015/4025/4045 Skid-Mounted Ozone Sanitation Systems Page 2 of 3 Material Safety Data Sheet Cont. Product Name AQUEOUS OZONE SOLUTION IV HEALTH HAZARD DATA Threshold Limit Value NOT DETERMINED Route of Exposure Inhalation Ingestion Skin Not Hazardous Eye Contact Hazard Exposure may cause mild eye irritation, but is not expected.
Page 24
Other Protective NOT REQUIRED Equipment IX SPECIAL PRECAUTIONS Certified testing of DEL Ozone systems by NSF (National Sanitation Foundation) has shown that Precautionary under normal conditions of use, aqueous solutions containing low levels of ozone gas dissolved in Labeling potable water do not present a safety hazard when contact to the individual is incidental. When...
After this information is provided, DEL Ozone may release a RETURN GOODS AUTHORIZATION (RGA) NUMBER. After receiving the RGA number the part in question must be returned to DEL Ozone, freight prepaid, with the RGA number clearly marked on the outside of the package. All preauthorized defective parts must be returned to DEL Ozone within thirty (30) days.
Need help?
Do you have a question about the AGW-4015 and is the answer not in the manual?