Operating Manual
The instruction at memory address 7 should be changed from End Program to Step & Repeat X. To
register a Step & Repeat X instruction at memory address 7, do the following:
1
Press the
7 is shown in the display.
Press the Enter key, then press the
2
change to page 2. Select Step & Repeat by pressing
the key 3.
Type 1 to select X direction, then press ENTER.
3
The display will prompt you for the Start Addr:
The start address is the memory address of the first
instruction, which is part of this Step & Repeat group.
4
In our example, we want to repeat all instructions
starting with memory address number 4.
Type 4 to specify memory address 4, then press
ENTER.
Type 2 to specify two columns, then press ENTER.
5
Instruction
or
keys until memory address
- Page 46 -
Display Shows
ADDR: 7
End Program
Step & Repeat
Address, 7
-----.Y,
key to
Start Address,
Columns (X):
Rows (Y):
Step & Repeat
Address, 7
-----.Y, 1
Start Address,
Columns (X):
Rows (Y):
[w+] Address [w-]Label
Step & Repeat
Address, 7
-----.Y, 1
Start Address, 4
Columns (X):
Rows (Y):
Step & Repeat
Address, 7
-----.Y, 1
Start Address, 4
Columns (X): 2
Rows (Y):
PROG: 20
Need help?
Do you have a question about the EQ RB20 500D and is the answer not in the manual?