Only use the power adaptor supplied with
your energizer, or a genuine Patriot
replacement.
See Safety information on page 5 for power
adaptor care instructions.
_ìáäÇáåÖ=~å=ÉäÉÅíêáÅ=ÑÉåÅÉ=
For information about building an electric
fence, refer to the Patriot website
www.patriotglobal.com.
fåëí~ääáåÖ=~å=É~êíÜ=ëóëíÉã=
Select a suitable site for the earth system.
Sites need to be at least 10 m (33') from other
earth systems (e.g. telephone, mains power or
the earth system of another energizer).
Drive earth rods into the soil. The table below
specifies the minimum number of 2 m (6'6")
earth rods recommended for an earthing
system:
båÉêÖáòÉê=
Patriot P5
Patriot P10
Patriot P20
Patriot P30
4
b~êíÜ=êçÇë=
1
2
3
4
p~ÑÉ=ÉäÉÅíêáÅ=ÑÉåÅÉ=
ÅçåëíêìÅíáçå=
Warning! Read before use.
An electric fence can be hazardous when
there is a risk of entrapment or entanglement,
or other hazards exist. Serious injury or death
may result. Take all steps to avoid the risk of
entrapment or entanglement. This safety
information should be read in conjunction
with Requirements for electric animal fences
on page 5.
e~ò~êÇë=
Do not climb through or under an electric
fence. If it is necessary to cross an electric
fence use a gate or specially designed
crossing point.
Do not allow young or infirm persons to use
this energizer without supervision. Do not
allow young children to play with this
energizer or near an electric fence or
electrified wires.
Do not electrify barbed wire.
Do not support off-set electrified wires less
than 150 mm (6") from a barbed wire
fence.
Do not electrify any fence construction
which could lead to entanglement of
persons or animals. We recommend for
instance, that no more than one electrified
off-set wire be supported on either side of a
barbed wire or mesh fence.
Do not supply an electric fence from two
energizers.
Do not allow electrified wires from two
energizers on the same or adjacent
properties to be less than 2 m (6'6") apart.
Do not place energizer earth electrodes
within 10 m (33') of any part of a power
supply earth system or telecommunications
earth system.
Do not run electric fence wires above or
close to overhead power or communication
lines.