Reference Information; Specifications - Maxwell VWC 1000 50TDC Manual

Table of Contents

Advertisement

Reference Information

Specifications

Max. Pull Rating
Chain Speed (Normal Working Load)
Chain Size
Gearbox Ratio
Motor Rating (Electric)
Current at normal working loads - 12v
Current at normal working loads - 24v
Hyd. Motor Max. Recommended Flow
Hyd. Motor Max. Recommended
Pressure
Hyd. Motor Ports
Hyd. Oil
26
VWC & VWCLP 1000
456kg (1000 lbs)
20 m/min (65 ft/min)
6-10mm (1/4" - 3/8") short link
44:1
1000w
120-160A
100-140A
20 l/min (5.3 US Gal/min)
100 Bar (1450 psi)
SAE 8 ( 3/4" 16 UNF )
Viscosity ISO 32 - ISO 68 @ 20-50ºC *
*Suitable oils: Shell Rimula X 15W-40; Shell Myrina
M 15W-40; Penzoil SAE 10W-40; Texaco 2109 SAE
15W; Texaco 1814 SAE 10W40. BP HLPHM 32-68;
Castrol Hysin AWS 32-68; BP Autrans T0410.
1000 1500 Windlass
VWC & VWCLP 1500
680kg (1500 lbs)
17 m/min (56ft/min)
56:1
1200w
160-200A
140-180A
138 Bar (2000 psi)
Vetus-Maxwell APAC Ltd

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents