In this document Introduction ..................... 1 Features ......................1 About your MX-65xx ..................2 Front panels ..................... 2 Rear panels ....................3 Remote control..................4 About EDIDs ..................... 5 Routing ......................5 Checking the status of an output..............6 Muting and unmuting video and audio on specific outputs ..... 6 Muting and unmuting video and audio on all outputs ......
Page 4
To update your firmware from a USB drive ......16 To update your firmware from a file on your computer ... 16 Specifications ....................17 Parts and ordering ..................18 Regulatory compliance ................. 18 Contact us ...................... 20 tvONE NCSA................20 tvONE EMEA ................20...
Introduction The MX-65xx Matrix Switcher Series is designed to allow the distribution of HDMI 2.0a (with HDCP) sources to multiple display devices independently or all at the same time using an intuitive front panel, infrared remote control or our control software, MX-tools. The MX-65xx series is the perfect solution for all your installations including home theaters, classrooms or conference rooms that demand high levels of performance and superior 4:4:4 4K/60 image...
Press to execute selected route or recalling a preset Clear Press to clear the selected inputs and outputs when routing Lock Press to lock all front panel buttons Preset Press to enter preset mode for saving or recalling presets tvONE...
Rear panels Name Description Input HDMI inputs Output HDMI outputs This USB is for Firmware updates only Ethernet Control port for TCP/IP commands System IR In IR input for control via Infrared when using an IR extender Serial port to control This device via RS232 RS232 commands.
Turn off output’s video and audio STATUS Preset output status SAVE Preset Save PRESET Load Preset DEFAULT EDID Begin default EDID selection LEARN EDID Begin EDID learning from one output CLEAR Clear the previous IR operation procedure TAKE Trigger the previous setting Reserved Reserved tvONE...
About EDIDs You only need to manually copy an EDID to an input if you have a display connected to the HDMI output port that cannot play audio and video properly. Sources output the lowest standards in audio format and video resolutions to be commonly acceptable among all HDMI displays.
2. Press the buttons for the outputs you want to mute or unmute. 3. Press TAKE. Muting and unmuting video and audio on all outputs On the buttons of the front panel: 1. Press MUTE. 2. Press ALL. 3. Press TAKE. tvONE...
Clearing a selection On the buttons of the front panel: To clear all selections, press CLEAR. ▪ Saving presets Finish routing before you save presets. The input or output button you choose becomes the new preset number. On the buttons of the front panel: 1.
13. 4k2k@30-3D-BITSTR(7.1ch) 14. 4k2k@60-420-3D-PCM2CH(2ch) 15. 4k2k@60-420-3D-BITSTR(7.1ch) 16. 4k2k@60-3D-PCM2CH(2ch) 17. 4k2k@60-3D-BITSTR(7.1ch) On the buttons of the front panel: 1. Press and hold MUTE until it flashes. 2. Press an input button to select an input to restore. 3. Press TAKE. Restoring is finished when ALL starts flashing. On the remote control: 1.
Power on. Enter standby mode. Connect to and control your MX-65xx with RS-232. Connect to and control your MX-65xx with TCP/IP. Select a COM port. Use this with RS-232. First launch When you first launch MX-Tools, select your MX-65xx model. tvONE...
Routing Routing For each output, select an input from the list. ▪ Loading presets 1. Select a stored preset from Recall Presets. 2. Select Recall. Saving presets 1. Select a preset from Save Presets. 2. Select Save. MNL-MX-65xx V1.00...
31. 4k2k@60-420-3D-PCM2CH(2ch) 32. 4k2k@60-420-3D-BITSTR(7.1ch) 33. 4k2k@60-3D-PCM2CH(2ch) 34. 4k2k@60-3D-BITSTR(7.1ch) To copy a default EDID to an input 1. Select an EDID from From Default. 2. Select an input from To. 3. Select Apply. Copying an EDID from an output to an input 1.
Rename Renaming inputs, outputs, and presets Enter a new name for the preset. ▪ Loading names for inputs, outputs, and presets from your MX-65xx Select Read for either inputs and outputs, or presets. ▪ tvONE...
System Cloud settings are not currently available. Getting IP information from your MX-65xx 1. Select DHCP. 2. Select Read. Entering static IP information The default static IP is 192.168.1.123. 1. Select Static. 2. Enter your IP address, mask, and gateway. 3.
(Update from USB) Start. To update your firmware from a file on your computer 1. Enter the IP address of your MX-65xx. 2. Select Load File and navigate to the new firmware file. 3. Select (Upload from NET) Start. tvONE...
Dimensions MX-6588: 44 x 440 x 220 mm H x W x D (1.7" x 17.3" x 8.6") MX-6544: 42 x 440 x 177mm (1.6" x 17.3" x 6.9") Weight (Net) MX-6588: 2.7 kg (5.9 lbs) MX-6544: 2.4 kg (5.2 lbs) Power supply MX-6588: 12V 7.5A DC...
PS-12-75-IEC-LK Replacement PSU 12v 7.5A with IEC 3 pin connector for MX-6588 PS-12-20-IEC-C8-LK Replacement PSU 12v 2A with IEC 2 pin connector for MX-6544 IRC-6 Replacement 28 key IR Remote for the MX-6588 and MX-6544 Regulatory compliance This product has been tested for compliance with appropriate FCC and CE rules and regulations.
Support: tech.europe@tvone.com Copyright 2019 tvONE. All rights reserved. Information in this document is subject to change without notice. The software described in this document is furnished under a license agreement or nondisclosure agreement. The software may be used or copied only in accordance with the terms of those agreements.
Need help?
Do you have a question about the MX-6544 and is the answer not in the manual?
Questions and answers