Kenwood NX-900 Service Manual page 65

800mhz digital transceiver
Hide thumbs Also See for NX-900:
Table of Contents

Advertisement

Item
Panel tuning mode
6. Tight
1) Adj item: [An SQLT]
Squelch
Adjust: [✳✳✳]
2) Adj item:
[Analog
[AnL SQLT]→
Narrow]
[AnC SQLT]→
[AnH SQLT]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [As SQLT]
Wide 4k]
Adjust: [✳✳✳]
2) Adj item:
[AsL SQLT]→
[AsC SQLT]→
[AsH SQLT]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±2.4kHz)
[Analog
1) Adj item: [Aw SQLT]
Wide 5k]
Adjust: [✳✳✳]
2) Adj item:
[AwL SQLT]→
[AwC SQLT]→
[AwH SQLT
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±3kHz)
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Tight
SSG
Squelch (Narrow)]
AF VTVM
2) Adj item: [Low],
Oscilloscope
[Center], [High]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±1.5kHz)
1) Adj item: [Tight
Squelch (Wide 4k)]
2) Adj item: [Low],
[Center], [High]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±2.4kHz)
1) Adj item: [Tight
Squelch (Wide 5k)]
2) Adj item: [Low],
[Center], [High]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±3kHz)
Measurement
Test-
Unit Terminal Unit
ANT
Ext.SP
connector
NX-900
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks