OBID ID CPRPOS Installation Manual

Card reader for contactless and contact smart cards

Advertisement

Quick Links

INSTALLATION
ID CPRPOS
Card reader for contactless and contact smart cards
final – public (B)
CPRPOS User Manual-01.doc
2015-07-27 – ID

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ID CPRPOS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OBID ID CPRPOS

  • Page 1 INSTALLATION ID CPRPOS Card reader for contactless and contact smart cards final – public (B) CPRPOS User Manual-01.doc 2015-07-27 – ID...
  • Page 2 ® ® OBID and OBID myAXXESS is a registered trademark of FEIG ELECTRONIC GmbH. All brand names, trademarks or logos are property of their respective owners. FEIG ELECTRONIC GmbH Page 2 of 18 ID CPRPOS User Manual-01.doc...
  • Page 3: Table Of Contents

    Installation ID CPRPOS Contents 1. Safety Instructions / Warning - Read before start-up ! 2. Characteristics of the ID CPRPOS 2.1. Scope of delivery ....................... 5 2.2. Available accessories and spare parts ................6 3. Dimensions 4. Connections 4.1. Ethernet interface ......................9 4.2.
  • Page 4 25 cm between the device and your cardiac pacemaker and not stay in an immediate proximity of the device respective the antenna for some time. FEIG ELECTRONIC GmbH Page 4 of 18 ID CPRPOS User Manual-01.doc...
  • Page 5: Characteristics Of The Id Cprpos

    ID CPRPOS has one SAM socket for ID-000 sized smart cards available. The ID CPRPOS can be connected and controlled by a host system via its RS232, USB or Ether- net interface. A connected host system is able to use the ID CPRPOS to communicate with smart cards and to control the user guidance via display, LED and buzzer.
  • Page 6: Available Accessories And Spare Parts

    RS232 connection cable incl. connector for power supply - Host connector: D-SUB 9 poles 4218.000.00 ID CAB.RS-C - Device connector: RJ-12 plug 6 poles - Power supply connector: RJ-12 jack 6 poles - Length: 2,0 m FEIG ELECTRONIC GmbH Page 6 of 18 ID CPRPOS User Manual-01.doc...
  • Page 7: Dimensions

    ID CPRPOS 3. Dimensions The ID CPRPOS is designed as desktop device. Its small form factor offers the possibility to place the reader directly on a sales counter or at a cashier station. Due to its rubber feet the reader is suitable for slippery undergrounds.
  • Page 8: Connections

    OBID classic-pro Installation ID CPRPOS 4. Connections    Figure 4: ID CPRPOS - position of the connectors  Ethernet interface (RJ-45)  USB interface (Mini-USB)  RS232 interface and power supply (RJ-12) NOTE: Only one host interface should be used at the same time. The usage of more than one host interface at the same time can cause malfunctions.
  • Page 9: Ethernet Interface

    ID CPRPOS 4.1. Ethernet interface The ID CPRPOS has an integrated 10/100 base-T network port with a common RJ-45 connector and an automatic “crossover correction”. With structured cabling CAT5 cables should be used. This ensures a reliable operation at 10 Mbps and 100 Mbps.
  • Page 10: Usb Interface

    ID CPRPOS 4.2. USB interface The ID CPRPOS is equipped with a USB on-the-go interface (USB mini jack). It allows a direct connection to a host system for controlling, configuration and firmware update of the device (ID CPRPOS is USB slave). In addition the ID CPRPOS offers the possibility to connect an external USB memory stick to the electronic unit by means of a USB on-the-go adaptor (ID CPRPOS is USB master).
  • Page 11: Rs232 Interface / Power Supply

    The device has to be supplied by a limited power supply (e.g. NEC Class 2/LPS power sup- ply) according IEC EN 60950, only! Reversing the polarity of the supply voltage may destroy the device. FEIG ELECTRONIC GmbH Page 11 of 18 ID CPRPOS User Manual-01.doc...
  • Page 12: Display And Led

    5. Display and LED display Figure 8: Display and LED The ID CPRPOS is equipped with a display as well as LED for user guidance and to show status information. 5.1. Display A connected host system can send text messages via the interfaces RS232, USB, and Ethernet to the integrated graphic display to realise a user guidance.
  • Page 13: Led

    ID CPRPOS 5.2. LED The three LEDs of the ID CPRPOS indicate the status of the device for the user. The device is equipped with 1 green, 1 yellow, and 1 red LED. Figure 9: Position of the LED on the ID CPRPOS...
  • Page 14: Installation Of A Secure Access Module (Sam)

    “CLOSE”. Afterwards the housing could be closed and the screws could be replaced. Figure 11: Installation of a SAM NOTE: The maximum tightening torque of the housing screws is 0,30 Nm. FEIG ELECTRONIC GmbH Page 14 of 18 ID CPRPOS User Manual-01.doc...
  • Page 15: Radio Approvals

    (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, mê- me si le brouillage est susceptible d'en compromettre le fonctionnement. FEIG ELECTRONIC GmbH Page 15 of 18 ID CPRPOS User Manual-01.doc...
  • Page 16 / IC certification. It is the responsibility of the operator and professional installer to en- sure that only certified systems are deployed in the United States / Canada. FEIG ELECTRONIC GmbH Page 16 of 18 ID CPRPOS User Manual-01.doc...
  • Page 17: Technical Data

    1 x LED red; 1 x LED yellow; 1 x LED green Optical indicator graphic LCD, 128 x 64 dots Acoustic indicator 1 internal buzzer 2 MByte Flash memory write cycles 100.000 FEIG ELECTRONIC GmbH Page 17 of 18 ID CPRPOS User Manual-01.doc...
  • Page 18 Environmental (shock, vibration, climate) IEC 60068 EN 60950 Health and Safety EN 50364 WEEE - 2002/96/EC Waste and Hazardous Substances RoHS - 2011/65/EC Function tested according to EMVCo Contactless/Contact Level 1 FEIG ELECTRONIC GmbH Page 18 of 18 ID CPRPOS User Manual-01.doc...

Table of Contents