Adcon A725 addSDI User Manual page 29

Table of Contents

Advertisement

IMME
D
ESCRIPTION
P
ARAMETER
R
ETURNS
R
EMARKS
R
EMOTE
E
XAMPLE
FDEV
D
ESCRIPTION
P
ARAMETER
Notice that if you need to get data that is not the last (newest) slot
remotely from a device, the ID must be supplied twice. If you need
to get the last slot stored, you can ignore the ID and the date/time
parameters:
9999 DATA
9999 DATA
13 12 2006 22 15 00 13 39 255 255 3 0 0 87 0 0 0 0
0 0 0 0 0 0 0 0 3311 0
#
Samples all inputs and immediately returns the sampled data.
Note: This command cannot be used to get data values from the
SDI-12 subsystem.
The ID of the requested subsystem; default is the standard A/D
subsystem of the A725 (ID=0).
A data block (see also "DATA" on page 25).
Note: The analog inputs are disabled on the A725.
GET only. The command needs a certain delay to execute (for
example, for the standard subsystem this delay amounts to two
seconds. The delay is necessary to allow for the sensors to settle
after applying power to them.
No.
IMME
4711 imme 13 12 2006 20 00 18 13 39 0 0 127
0 0 84
0 0 0
0 0 0
2209 0
#
Formats the internal memory (destroys all the data).
If the parameters are missing, the command will destroy all the
data in the EEPROM file. If a parameter is given, the EEPROM type
is defined (data won't be destroyed). The following EEPROM types
are currently defined:
CHAPTER 3
Using terminal commands
27

Advertisement

Table of Contents
loading

Table of Contents