Using terminal commands
The remote version is limited to a single frame. An example of such a command is
given below:
9999 DATA 9999 30/9/1999 14:50:00
9999 DATA
30 9 1999 14 54 55 21 37 255 255 77 0 0 0 0 89 156 126 20 0 0
0 0 0 0 0 0 0 3197 0
#
Notice that if you need to get data that is not the last (newest) slot remotely from a
device, you must supply the ID twice. If you need to get the last slot stored, you
can ignore the ID and the date/time parameters:
9999 DATA
9999 DATA
13 9 1999 19 26 36 21 37 255 255 79 0 0 0 0 87 148 149 15 0 0
0 0 0 0 0 0 0 3148 0
#

IMME

A
VAILABLE FOR
D
Samples all inputs and immediately returns the sampled data.
ESCRIPTION
P
The ID of the requested subsystem; default is the standard A/D subsystem of the
ARAMETER
A733 (ID=0).
Note:
Currently only the default subsystem is implemented on the A73x.
R
A data block (see also "DATA" on page 36).
ETURNS
R
GET only. The command needs a certain delay to execute (for example, for the
EMARKS
standard subsystem this delay amounts to two seconds. The delay is necessary to
allow for the sensors to settle after applying power to them.
R
No.
EMOTE
E
IMME
XAMPLE
15695 IMME 26 5 2003 17 18 28 21 37 0 0 127
0 554 0 0 84
0 0 0
9056 0
#

FDEV

A
VAILABLE FOR
D
Formats the internal memory (destroys all the data).
ESCRIPTION
P
If the parameters are missing, the command destroys all the data in the EEPROM
ARAMETER
file. If a parameter is given, the EEPROM type is defined (data won't be destroyed).
Following EEPROM types are currently defined:
R
Nothing.
ETURNS
R
SET only.
EMARKS
R
Yes, SET only.
EMOTE
E
FDEV 1
XAMPLE
38
A731
A732
A733
1016 2048 3072
A731
A732
A733
0 – 16 Kbytes (e.g. model 25128)
1 – 32 Kbytes (e.g. model 25256)
A733GSM
0 0 0
A733GSM
0 0 0