Maintaining and servicing the RTU
3. Unscrew the four screws of the plastic cover that holds the battery pack in
4. Remove the battery pack and replace it with a new one (obtainable from
5. Replace the plastic cover and screw the four screws back in.
6. Carefully remove the rubber gasket in the lid and replace it with the one
7. Insert the battery plug into the PCB connector.
8. Remount the lid, taking care that the rubber gasket sealing the box is properly
W
:
Be sure to mount the rubber gasket properly, so as to retain the unit's IP65
ARNING
environmental protection.
9. Screw the four screws back in, applying a moderate force.
22
Fig. 7:
place, then remove the cover. Fig. 8 shows the A733 battery pack inside the
RTU.
Adcon).
supplied with the battery.
seated.
Unplugging the PCB Connector
Fig. 8:
A733 Battery Pack