Changing of battery pack
72
Figure 58: Removing the battery connector from round collar, curved battery pack
Unplug the battery connector by pulling the collar away from the battery pack (Figure
above, left). You can support this by very carefully wedging a flat screwdriver between
the battery connector and the battery pack (Figure above, right). Be careful to avoid any
damage to the connector!
Figure 59: Battery connector and plugs on round collar, curved battery pack
Above you can see the battery socket (left) and pins (right). To attach a new battery
pack, exchange the O-ring on the battery plug and carefully plug the three threaded
battery pins into the socket.
Figure 60: Attachment of curved battery pack to round collar with two metal base plates (left)
and two Fastlock washers (right)
In older collars, the battery packs are fixed to the belt with six screws and three metal