Operation - Emerson KTM series Installation And Operation Manual

Jacketed ball valves
Table of Contents

Advertisement

KTM Jacketed ball valves
InstallatIon and operatIon manual

7 operaTion

1. Operation instruction
valve adjustment is performed through
lever handle/gear operation. turning the
shaft clockwise shuts the valve. check the
operation of the valve by stroking it to 'fully
open' and 'fully close'. either the hand
lever or the direction of the parallel flats
on the top of the shaft indicate the open
or closed position of the ktM ball valves.
(see Figure 4) For gear operated valves, the
position is indicated by the arrow-indicator
(see Figure 5).
2. gear operated valve adjustment
If the gear-operating mechanism indicator
does not correctly indicate the valve is
completely open or shut, adjust the opening
with the adjustment screw. For details, refer
to emerson sales /service office.
3. key-lock (option)
a locking device at the open and shut
positions can be provided to prevent
unauthorized or incorrect operation.
Unlock and detach the padlock otherwise
FIgURe 4
lever operated valve
valve closed
valve opened
locK pin and pad locK diMenSionS (mm)
valve nominal diameter (mm)
(full bore)
15 - 25
40 - 50
65 - 100
125 - 200
FIgURe 6.1
lock pin and pad lock (mm)
ød0
l
locking pins and stopper might break.
to lock the jacketed ball valves, use locks
of the sizes indicated in the table below.
Warning
1. Avoid using the valves in half opened position.
Since it may result in seat deformation or
leakage.
2. Operate the valves taking up a stable posture
from a set direction, after checking that the
specified handle is fastened by bolts/nuts.
Also, when operating the valve with spare
handle, please make sure that the handle
is reliably inserted into the shaft's end.
Insufficient insertion and forced operation of
the handle may result in damage or injury if
the handle slipps out.
3. Excessive handle operation may break the
lever, injure the operator, and/or deform the
stopper or the shaft, which may also result in
seat leakage.
4. Be careful in handling the valve where high
temperature fluid flows in the pipeline. The
heated valve may cause burn injury of bare
hands.
FIgURe 5
gear operational valve
Indicator
pin dimensions
d0
d
l
5.5
4.9
25
5.5
6.5
31
6.5
8.3
39
-
-
-
25
pad lock type
alpha no.
1000 - 25 m/m
1000 - 25 m/m
1000 - 25 m/m
1000 - 25 m/m
11.5
4